Results 231 to 240 of about 3,119,521 (274)

Study on the Return Voltage Function Model of Oil-Paper Insulation Medium Based on Optimization Algorithm

open access: yesAdvanced Materials Research, 2014
Based on the study of dielectric response theory and equivalent circuit of oil-paper insulation medium, this paper deduces the exponential decay type return voltage function model.It also proposes that rhe function can be resolved with the application of
An Li, Jin-ding Cai, Jingsong Zeng
exaly   +2 more sources
Some of the next articles are maybe not open access.

Related searches:

Return to Work After Low Voltage Electrical Injury

Journal of Burn Care & Research, 2008
Low voltage electrical injury is associated with minor or no cutaneous burns and its symptoms rarely appear on initial examination. The purpose of this study was to determine the ability to return to work among patients with low voltage electrical injury.
Kirstin, Theman   +3 more
openaire   +2 more sources

Investigation of Return Voltage Measurement for the Assessment of Power Transformers

2008 International Conference on Condition Monitoring and Diagnosis, 2008
Moisture and ageing in power transformer strongly influence the dielectric properties of oil/paper insulation system. Moisture measurement in oil sample generally gives inconclusive information since oil/paper moisture equilibrium is temperature dependent and takes a long time to be in equilibrium.
null Rui-gang Zhang   +3 more
openaire   +1 more source

Return voltage measurements on paper insulation of windings and cables

ICSD'98. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics (Cat. No.98CH36132), 2002
The RVM method is capable of detecting moisture in paper insulation, but its sensitivity is highly dependent on the geometry of the test object. The sensitivity depends on the electrode distance through oil and seems most sensitive when both electrodes are touching the paper insulation.
M.G.M. Megens, S. Rama, R. Ross
openaire   +1 more source

On Discharge Voltage and Return Voltage Curves for Absorptive Capacitors

Physical Review, 1942
Formulas for the initial slope of the discharge voltage and return voltage curves in absorptive capacitors are given and it is shown that the discharge voltage curves are limited by two threshold curves, one of them being directly proportional to the slope of the other one.
openaire   +1 more source

Experimental Analysis of Aged XLPE Cable Using Return Voltage Measurement

2024 21st International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology (ECTI-CON)
Supriyo Das, Ashok Narayan Tripathi
exaly   +2 more sources

Return voltage measurements of oil impregnated paper insulated transformers

Proceedings of 2005 International Symposium on Electrical Insulating Materials, 2005. (ISEIM 2005)., 2005
One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of the oil-paper insulation of power transformer is the return voltage measurement (RVM). Using RVM improves the ability to detect the content of water concentration and the ageing process in the oil-paper insulation system and can thus ...
M.H. Li   +4 more
openaire   +1 more source

Temperature dependence of return voltage characteristics [of power current transformers]

POWERCON '98. 1998 International Conference on Power System Technology. Proceedings (Cat. No.98EX151), 2002
Recently, return voltage measurements have been proposed for the diagnosis of HV power equipment, characterising the dielectric properties of their insulation systems. The application of the return voltage method for the diagnosis of HV current transformer insulation is presented in this paper.
A. Kozlovskis, J. Rozenkrons
openaire   +1 more source

Return voltage measurements: Theory and applications to charge injection monitoring

2008 13th International Symposium on Electrets, 2008
Charge injection is in many cases a step towards the breakdown of insulating materials. Although modern charge mapping techniques exist, they might be too expensive or difficult to use in an industrial laboratory environment, and an alternative solution for charge injection monitoring, especially on thin films, could be measurements of the return ...
Philippe Molinie   +2 more
openaire   +1 more source

The return of the true medium voltage dead tank circuit breaker

2003 IEEE PES Transmission and Distribution Conference and Exposition (IEEE Cat. No.03CH37495), 2004
Over recent years the dead tank concept which was inherited from bulk oil technology has shifted towards dog-house designs. The paper describes the features of a new generation of dead tank circuit breakers based on a design which has been developed using modern technical features such as vacuum interruption, oil free, gas insulation, and a sealed for ...
A. Bieri, X.F. Braud, L.T. Falkingham
openaire   +1 more source

Home - About - Disclaimer - Privacy