Results 31 to 40 of about 114,282 (294)

Revision of the Sheehan total knee arthroplasty [PDF]

open access: yesInternational Orthopaedics, 2005
The use of the Sheehan knee prosthesis extended from 1971 to 2002. It incorporated a semi-constrained hinge with intra-medullary stems cemented into the femur and tibia. While some authors have reported excellent short-term results, others have reported revision rates of up to 31% at 5--10 years.
C, Hurson   +4 more
openaire   +2 more sources

Variability of Sagittal Plane Proximal Tibial Morphology and Its Effect on Stem Placement in Total Knee Arthroplasty

open access: yesArthroplasty Today, 2022
The tibial joint line is offset posteriorly relative to the tibial sagittal anatomic axis. This can have consequences when using stemmed implants during total knee arthroplasty. We retrospectively analyzed native knee lateral radiographs in 100 patients.
Eric S. Secrist, MD   +3 more
doaj   +1 more source

Revision total knee arthroplasty versus primary total knee arthroplasty

open access: yesBone & Joint Open, 2020
Introduction The primary aim of this study was to describe a baseline comparison of early knee-specific functional outcomes following revision total knee arthroplasty (TKA) using metaphyseal sleeves with a matched cohort of patients undergoing primary ...
P. Stirling   +3 more
semanticscholar   +1 more source

Bone Defects in Revision Total Knee Arthroplasty

open access: yesRevista Brasileira de Ortopedia, 2021
The increase in the number of revision total knee arthroplasty surgeries has been observed in recent years, worldwide, for several causes. In the United States, a 601% increase in the number of total knee arthroplasties, between 2005 and 2030, is ...
Alan de Paula Mozella   +1 more
doaj   +2 more sources

Trunnion Failure in Revision Total Knee Arthroplasty

open access: yesArthroplasty Today, 2021
In revision total knee arthroplasty, joint kinematics must be maintained amid bone and ligamentous insufficiency. Current modular designs address defects while allowing for intraoperative prosthesis customization through a variety of stem extensions and ...
Samir Chihab, MD   +3 more
doaj   +1 more source

The effect of operative time on in-hospital length of stay in revision total knee arthroplasty.

open access: yesAnnals of Translational Medicine, 2019
Background Revision total knee arthroplasty (TKA) is associated with increased rates of infections, readmissions, longer operative times, and lengths-of-stay (LOS) compared to primary TKA.
L. Garbarino   +9 more
semanticscholar   +1 more source

Revision total knee arthroplasty using a custom tantalum implant in a patient following multiple failed revisions

open access: yesArthroplasty Today, 2017
The number of revision total knee arthroplasty procedures performed annually is increasing and, subsequently, so is the number of patients presenting following a failed revision.
Colin A. McNamara, BS   +5 more
doaj   +1 more source

Bone Defects in Revision Total Knee Arthroplasty and Management

open access: yesOrthopaedic Surgery, 2019
This article reviews the recent updates in revision of total knee arthroplasty (RTKA). We reviewed the recent articles on RTKA in databases including PubMed, Google Scholar, and SCOPUS.
P. Lei, Ruyin Hu, Yi-He Hu
semanticscholar   +1 more source

Tapered modular fluted titanium stems for femoral fixation in revision total knee arthroplasty

open access: yesArthroplasty Today, 2018
Consensus regarding femoral stem fixation options in revision total knee arthroplasty remains controversial. Tapered, modular, fluted titanium (TMFT) stems have an excellent track record in total hip arthroplasty for their ability to provide axial and ...
Jeffrey B. Stambough, MD   +3 more
doaj   +1 more source

3D‐Printed Titanium Gyroid Scaffold Structure Integrated With Tough Hybrid Materials for Cartilage Replacement

open access: yesAdvanced Engineering Materials, EarlyView.
This study proposes a potential device design for joint cartilage replacement. Silica‐polytetrahydrofuran (SiO2‐PolyTHF) hybrids with customizable mechanical properties were developed to mimic the characteristics of a natural meniscus. These were synthesized through a two‐pot sol–gel hybrid process.
Yu‐Chien Lin   +12 more
wiley   +1 more source