Results 21 to 30 of about 114,863 (150)

Power frequency AC voltage measurement based on double wound Rogowski coil

open access: yesHigh Voltage, 2017
This study presents a technique for power frequency AC voltage measurement. The proposed technique utilises a capacitor having a low capacitance in addition to a double wound Rogowski coil.
Mohamed E. Ibrahim, Amr M. Abd-Elhady
doaj   +1 more source

SOME CONSIDERATIONS OF DESIGNING A HIGH PERFORMANCE ROGOWSKI COIL FOR PULSED CURRENT MEASUREMENT

open access: yesElectrica, 2005
Rogowski coil is made having nonmagnetic material in a core, which results in that Rogowski coil has typically been used to measure large pulsed currents.
LI WEIBO, MAO CHENGXIONG, LU JIMING
doaj   +2 more sources

Smart Characterization of Rogowski Coils by Using a Synthetized Signal

open access: yesSensors, 2020
With the spread of new Low-Power Instrument Transformers (LPITs), it is fundamental to provide models and characterization procedures to estimate and even predict the LPITs’ behavior. In fact, distribution system operators and designers of network models
Alessandro Mingotti   +2 more
doaj   +1 more source

Textile‐based sensors for electrical current measurement in three‐phase cables

open access: yesIET Smart Grid, 2022
There is much discussion about the implementation and benefits of smart electricity networks. However, the reality is that the instrumentation needed at low voltage is too expensive for large‐scale deployment.
Dani Strickland   +5 more
doaj   +1 more source

STUDY OF NOVEL MEASUREMENT INSTRUMENTATION INSPECTING THE STATE OF THE CELL DURING ELECTROLYTIC ROASTING PROCESS

open access: yesElectrica, 2003
In the roasting process stageeach component of the cell of aluminum performs unsteadily. Monitoring the currents of both anodes and cathodes of the cell at regular intervals is quite necessary.
Li Weibo   +3 more
doaj   +2 more sources

An improved distance relay based on electronic transformer by using instantaneous value after equal transfer processes

open access: yesIET Generation, Transmission & Distribution, 2022
This paper analyses the formation mechanism of the transmission distortion of electronic voltage transformer, and points out that the integrator will magnify the transient transfer error and superimpose the dynamic additional component on the output ...
Baowei Li   +4 more
doaj   +1 more source

The circuit parameters measurement of the SABALAN-I plasma focus facility and comparison with Lee Model

open access: yesResults in Physics, 2017
The circuit parameters are investigated in a Mather-type plasma focus device. The experiments are performed in the SABALAN-I plasma focus facility (2 kJ, 20 kV, 10 µF). A 12-turn Rogowski coil is built and used to measure the time derivative of discharge
F.S. Karimi   +4 more
doaj   +1 more source

Expansion of cylindrical tubular workpieces on high-voltage magnetic-pulse installation with controlled vacuum discharger

open access: yesElectrical engineering & Electromechanics, 2021
Purpose. An experimental verification of the existence of a range of values for the parameters of the capacitive energy storage of the magnetic-pulse installations with controlled vacuum discharger, in which, with a high probability, there is a «cut» of ...
L. A. Ljutenko, V. M. Mikhailov
doaj   +1 more source

Post‐Arc Transient Dielectric Recovery Characteristics of Vacuum Interrupter in the Large‐Capacity Generator Circuit Breaker

open access: yesHigh Voltage, Volume 11, Issue 4, Page 999-1010, August 2026.
ABSTRACT Large‐capacity generator circuit breaker (GCB) based on vacuum interrupter technology is the key power equipment to ensure the safe operation of the power system. When the short‐circuit current was forced to cross zero, the large‐capacity GCB was difficult to generate a zero‐voltage environment through freewheeling, the vacuum interrupter (VI)
Xiangyu Han   +8 more
wiley   +1 more source

Reactive Nitrogen–Dominant Plasma Accelerates Diabetic Wound Healing Through Regulated Angiogenesis and TGF‐β Normalisation

open access: yesInternational Wound Journal, Volume 23, Issue 6, June 2026.
ABSTRACT Chronic diabetic wounds persist because of impaired angiogenesis, dysregulated transforming growth factor beta activity and delayed matrix remodelling. Non‐thermal atmospheric pressure plasma therapy represents a potential non‐pharmacologic approach to overcome these barriers.
Yu‐Pin Cheng   +8 more
wiley   +1 more source

Home - About - Disclaimer - Privacy