Results 101 to 110 of about 2,228 (213)

An Obstacle Avoidance Strategy for AUV Based on State-Tracking Collision Detection and Improved Artificial Potential Field

open access: yesJournal of Marine Science and Engineering
This paper proposes a fusion algorithm based on state-tracking collision detection and the simulated annealing potential field (SCD-SAPF) to address the challenges of obstacle avoidance for autonomous underwater vehicles (AUVs) in dynamic environments ...
Yueming Li   +4 more
doaj   +1 more source

A Refined Self-Tuning Filter-Based Instantaneous Power Theory Algorithm for Indirect Current Controlled Three-Level Inverter-Based Shunt Active Power Filters under Non-sinusoidal Source Voltage Conditions

open access: yesEnergies, 2017
In this paper, a refined reference current generation algorithm based on instantaneous power (pq) theory is proposed, for operation of an indirect current controlled (ICC) three-level neutral-point diode clamped (NPC) inverter-based shunt active power ...
Yap Hoon   +3 more
doaj   +1 more source

A Lyapunov Stability Theory-Based Control Strategy for Three-Level Shunt Active Power Filter

open access: yesEnergies, 2017
The three-phase three-wire neutral-point-clamped shunt active power filter (NPC-SAPF), which most adopts classical closed-loop feedback control methods such as proportional-integral (PI), proportional-resonant (PR) and repetitive control, can only output
Yijia Cao   +4 more
doaj   +1 more source

Power Quality Comparative Analysis between UPF and SAPF

open access: yesJournal of Energy and Power Engineering, 2021
null Nicolae Badea   +2 more
openaire   +1 more source

Improvement of the Source Current Quality for a Shunt Active Power Filter Operating Using Hysteresis Technique with Stabilized Switching Frequency

open access: yesEnergies
Determining the current reference for a shunt active power filter (SAPF) can be carried out in many ways. Once the reference is determined, it can be shaped by SAPF switches with the use of pulse width modulation (PWM)/hysteresis control techniques ...
Andrzej Szromba
doaj   +1 more source

Development of Shunt Active Power Filter for Harmonic Reduction using Synchronous Reference Frame with Space Vector Pulse Width Modulation

open access: yesNigerian Journal of Technological Development, 2020
The work aims at development of Shunt Active Power Filter (SAPF) for harmonic reduction. The current harmonics are being caused by nonlinear characteristic of power electronics based equipments which increase power losses and in turn reduce power quality.
Sijuwade Akanni Akintade   +2 more
doaj  

DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter [PDF]

open access: yes, 2017
Shunt active power filter (SAPF) is the most effective solution for current harmonics. In its controller, DC-link capacitor voltage regulation algorithm with either proportional-integral (PI) or fuzzy logic control (FLC) technique has played a ...
Mailah, Nashiren Farzilah   +2 more
core  

Power Quality Improvement by Harmonic Reduction Using Three Phase Shunt Active Power Filter with p-q & d-q Current Control Strategy [PDF]

open access: yes, 2015
With the widespread use of power electronics devices such as rectifier, inverter etc. in power system causes serious problem relating to power quality. One of such problem is generation of current and voltage harmonics causing distortion of load waveform,
Bhadra , Dibyendu, Meena , Rajnish Kumar
core  

On Integration Policies and Schooling [PDF]

open access: yes
This paper proposes a reform for school allocation procedures in order to help integration policies reach their objective. For this purpose, we suggest the use of a natural two-step mechanism. The (stable) first step is introduced as an adaptation of the
Alcalde, Jose, Subiza, Begoña
core   +1 more source

Generalized one-cycle current controller for improved SAPF power quality management

open access: yesInternational Journal of Electrical Power & Energy Systems
[EN] Current controllers are used in shunt active power filters to enhance the performance of electrical power systems by improving power quality and energy efficiency. Nonlinear current controllers are preferred in systems with nonlinear and dynamic loads due to their robust and rapid tracking of varying reference currents.
S. Orts-Grau   +4 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy