Results 1 to 10 of about 1,002 (156)

A Review of Control Technique Applied in Shunt Active Power Filter (SAPF) [PDF]

open access: yesEngineering and Technology Journal, 2022
In recent years, electronic transformers and electronic devices (nonlinear loads) have increased. These loads are the source of harmonics (non-sinusoidal and distorted waves) and the interactive force that affects the performance of the power system ...
Ayad Hadi, Ekhlas Thjeel, Ali Nahar
doaj   +2 more sources

A fault tolerance method based on switch redundancy for shunt active power filter

open access: yesEnergy Reports, 2021
In order to improve the reliability of the shunt active power filter(SAPF) system, the fault-tolerant control strategy of the system is studied in this paper.
Dongdong Chen   +3 more
doaj   +3 more sources

Power quality optimization framework for three phase microgrids with grid tied solar PV and battery storage under nonlinear loads [PDF]

open access: yesScientific Reports
Worsening power quality driven by non-linear and converter dominated loads poses a significant challenge in renewable integrated microgrids. This paper develops and evaluates a coordinated source-filter control framework that (i) determines the optimal ...
Muhammad Saleh Waseem Abbasi   +5 more
doaj   +2 more sources

Development of Shunt Active Power Filter for Harmonic Reduction using Synchronous Reference Frame with Space Vector Pulse Width Modulation [PDF]

open access: yesNigerian Journal of Technological Development, 2020
The work aims at development of Shunt Active Power Filter (SAPF) for harmonic reduction. The current harmonics are being caused by nonlinear characteristic of power electronics based equipments which increase power losses and in turn reduce power quality.
Sijuwade Akanni Akintade   +2 more
doaj   +3 more sources

Implementation of a hybrid neural network control technique to a cascaded MLI based SAPF [PDF]

open access: yesScientific Reports
This paper presents a naïve back propagation (NBP) based $$i\cos \emptyset$$ i cos ∅ technique implemented to a cascaded multilevel inverter (MLI) based shunt active power filter (SAPF).
Rashmi Rekha Behera   +4 more
doaj   +2 more sources

Adaptive Frequency-Based Reference Compensation Current Control Strategy of Shunt Active Power Filter for Unbalanced Nonlinear Loads

open access: yesEnergies, 2019
The shunt active power filter (SAPF) is an effective means for the modification of power quality. However, the compensation performance of SAPF would be deteriorated when the unbalanced nonlinear loads are present in the power system.
Cheng-I Chen   +3 more
doaj   +3 more sources

An optimized proportional resonant current controller based genetic algorithm for enhancing shunt active power filter performance

open access: yesInternational Journal of Electrical Power & Energy Systems
Current harmonics produced by nonlinear loads have destructive effects that affect the power quality of the power system and cause serious problems throughout the network.
Behnam Amini   +2 more
doaj   +3 more sources

Experimental Validation of a Current-Source Converter with Reduced Dc-link Operating as Shunt Active Power Filter [PDF]

open access: yesEAI Endorsed Transactions on Energy Web, 2021
Nowadays, the majority of electronic equipment behaves as nonlinear loads, introducing power quality problems into the power grid, namely, current harmonics and low power factor. These problems contribute to reduce the efficiency of the
Catia Oliveira   +5 more
doaj   +1 more source

Sliding mode controller for four leg shunt active power filter to eliminating zero sequence current, compensating harmonics and reactive power with fixed switching frequency [PDF]

open access: yesSerbian Journal of Electrical Engineering, 2015
In this paper, the four leg inverter controlled by the three dimensional space vector modulation (3D SVM) is used as the shunt active power filter (SAPF) for compensating the three phase four wire electrical network, by using the four leg ...
Chebabhi Ali   +3 more
doaj   +1 more source

Self tunning filter for three levels four legs shunt active power filter with fuzzy logic controller

open access: yesActa Polytechnica, 2021
The low harmonic distortion and reduced switching losses are the advantages of using the multilevel inverter. For this purpose, the three-level inverter is used in this paper as a three-phase four-leg shunt active power filter (SAPF). The SAPF is used to
Dahmane Djendaoui   +3 more
doaj   +1 more source

Home - About - Disclaimer - Privacy