A Review of Control Technique Applied in Shunt Active Power Filter (SAPF) [PDF]
In recent years, electronic transformers and electronic devices (nonlinear loads) have increased. These loads are the source of harmonics (non-sinusoidal and distorted waves) and the interactive force that affects the performance of the power system ...
Ayad Hadi, Ekhlas Thjeel, Ali Nahar
doaj +2 more sources
A fault tolerance method based on switch redundancy for shunt active power filter
In order to improve the reliability of the shunt active power filter(SAPF) system, the fault-tolerant control strategy of the system is studied in this paper.
Dongdong Chen +3 more
doaj +3 more sources
Power quality optimization framework for three phase microgrids with grid tied solar PV and battery storage under nonlinear loads [PDF]
Worsening power quality driven by non-linear and converter dominated loads poses a significant challenge in renewable integrated microgrids. This paper develops and evaluates a coordinated source-filter control framework that (i) determines the optimal ...
Muhammad Saleh Waseem Abbasi +5 more
doaj +2 more sources
Development of Shunt Active Power Filter for Harmonic Reduction using Synchronous Reference Frame with Space Vector Pulse Width Modulation [PDF]
The work aims at development of Shunt Active Power Filter (SAPF) for harmonic reduction. The current harmonics are being caused by nonlinear characteristic of power electronics based equipments which increase power losses and in turn reduce power quality.
Sijuwade Akanni Akintade +2 more
doaj +3 more sources
Implementation of a hybrid neural network control technique to a cascaded MLI based SAPF [PDF]
This paper presents a naïve back propagation (NBP) based $$i\cos \emptyset$$ i cos ∅ technique implemented to a cascaded multilevel inverter (MLI) based shunt active power filter (SAPF).
Rashmi Rekha Behera +4 more
doaj +2 more sources
The shunt active power filter (SAPF) is an effective means for the modification of power quality. However, the compensation performance of SAPF would be deteriorated when the unbalanced nonlinear loads are present in the power system.
Cheng-I Chen +3 more
doaj +3 more sources
Current harmonics produced by nonlinear loads have destructive effects that affect the power quality of the power system and cause serious problems throughout the network.
Behnam Amini +2 more
doaj +3 more sources
Experimental Validation of a Current-Source Converter with Reduced Dc-link Operating as Shunt Active Power Filter [PDF]
Nowadays, the majority of electronic equipment behaves as nonlinear loads, introducing power quality problems into the power grid, namely, current harmonics and low power factor. These problems contribute to reduce the efficiency of the
Catia Oliveira +5 more
doaj +1 more source
Sliding mode controller for four leg shunt active power filter to eliminating zero sequence current, compensating harmonics and reactive power with fixed switching frequency [PDF]
In this paper, the four leg inverter controlled by the three dimensional space vector modulation (3D SVM) is used as the shunt active power filter (SAPF) for compensating the three phase four wire electrical network, by using the four leg ...
Chebabhi Ali +3 more
doaj +1 more source
Self tunning filter for three levels four legs shunt active power filter with fuzzy logic controller
The low harmonic distortion and reduced switching losses are the advantages of using the multilevel inverter. For this purpose, the three-level inverter is used in this paper as a three-phase four-leg shunt active power filter (SAPF). The SAPF is used to
Dahmane Djendaoui +3 more
doaj +1 more source