Simulation study on the material stress distribution respect to different angle of ECAP [PDF]
This research study focused on the influence of channel angle towards stress distribution of material aluminium alloy 5083. The size of the grain is related to the mechanical properties of material.
Kamaruddin, Akmalia Shahira +1 more
core +1 more source
Current technological developments generally use sophisticated equipment which is categorized as a non-linear load. The massive use of non-linear loads causes side effects on the quality of electric power. Electric power systems that are connected to non-linear loads will experience distortion in current and voltage by harmonics due to the engineering ...
Achmad Rifa’i +2 more
openaire +2 more sources
Synchronous Reference Frame with Finite Impulse Response Filter for Operation of Single-phase Shunt Active Power Filter [PDF]
Power Quality (PQ) has been recognized as one of the main issues in electricity supply worldwide after the invention of nonlinear load. In 2017, PQ problem leads to significant economic losses in the Pan European region.
Tham Zhen Ye +2 more
doaj +1 more source
Grid Power Quality Enhancement Using Fuzzy Control-Based Shunt Active Filtering [PDF]
Active filtering has proved efficient for the mitigation of harmonics in distribution grids. This paper deals with the design of fuzzy control strategies for a three-phase shunt active filter to enhance the power quality via the regulation of the DC bus ...
Allaoui, Tayeb +3 more
core +1 more source
Control of Three-Phase Shunt Active Power Filter SAPF by Instantaneous Reactive Power Theory [PDF]
Use of nonlinear loads has been increased in large extent in industries now a days which injects harmonic currents in supply system. These harmonics creates power quality issue. Shunt Active Power Filter SAPF is the popular and efficient solution to reduce these harmonics.
openaire +2 more sources
Comparison of current-source and voltage-source shunt active power filters for harmonic compensation and reactive power control [PDF]
This paper presents the comparison between two three-phase Shunt Active Power Filters (SAPFs), one with Current-Source Inverter (CSI) and the other with Voltage-Source Inverter (VSI), which are used to compensate current harmonics and to ...
Afonso, João L. +5 more
core +1 more source
This paper presents a non-iterative technique that generates reference current to manage operation of a three-phase four-wire shunt active power filter which employs a three-leg split capacitor voltage source inverter (VSI) topology.
Yap Hoon, Mohd Amran Mohd Radzi
doaj +1 more source
Performance evaluation of Modified Widrow-Hoff ADALINE under effect of photovoltaic with shunt active power filter [PDF]
This paper investigates performances of Modified Widrow-Hoff ADALINE as harmonics extraction algorithm under effect of photovoltaic (PV) integrated with shunt active power filter (SAPF).
Abd Rahim, Nasrudin +4 more
core +1 more source
Marketing macro environment during the pandemic Covid-19 [PDF]
Without a doubt, COVID-19 is indeed a disease caused by a recently discovered coronavirus strain, a form of a virus known to cause human respiratory infections. On January 24, 2020, the first case of Malaysia with COVID-19 was detected.
Abu Seman, Noor Aslinda +2 more
core
A modified artificial neural network (ANN) algorithm to control shunt active power filter (SAPF) for current harmonics reduction [PDF]
Proliferation of nonlinear loads /devices in power systems generates a major concern to power system engineers, courtesy of its severe contamination effects (polluting the distribution networks with current harmonics). This paper depicts artificial intelligence (AI) application on resolving the power quality problem mentioned above by using the ...
Aliyu Sabo +3 more
openaire +1 more source