Results 61 to 70 of about 2,228 (213)

An Efficient Multi‐Core DSP Power Management Controller

open access: yesEngineering Reports, Volume 7, Issue 4, April 2025.
This work proposes a power management controller for multi‐core DSP architectures, specifically designed for FT‐xDSP. The primary contributions include a clamp request control unit to ensure system stability during asynchronous resets, and a configurable state transition counter that optimizes clock transitions.
Jian Huang   +4 more
wiley   +1 more source

Selective SAPF for Harmonic and Interharmonic Compensation Using an Adaptive Kalman Filter-Based Identification Method

open access: yesApplied Sciences
This work presents the application of a hybrid adaptive Kalman filter (HAKF) for the implementation of a shunt active power filter (SAPF), enabling selective harmonic and interharmonic compensation in real time.
Germán Martínez-Navarro   +1 more
doaj   +1 more source

DFPI-based Control of the DC-bus Voltage and the AC-side Current of a Shunt Active Power Filter [PDF]

open access: yes, 2016
The current paper presents a continuation of an earlier research and purposes to enhance the performances of the studied system. While the double fuzzy PI (DFPI) control was applied only on the DC capacitor bus in a previous work it is applied here also ...
Djeghloud, H. (Hind)   +2 more
core  

Double soft-computing techniques based triple functionalities for shunt active power filter with voltage source inverter topology [PDF]

open access: yes, 2015
Firstly, a unified adaptive linear neurons based fundamental component extraction algorithm for dual roles is developed; to generate and synchronize a reference current with respect to the phase and the frequency of supply voltage.
Abd Rahim, Nasrudin   +4 more
core   +1 more source

Impacts of Nonlinear Loads on the Power Quality of Solar Microgrids and Proposed Mitigation Strategies

open access: yesEnergy Science &Engineering, Volume 13, Issue 4, Page 1960-1982, April 2025.
Nonlinear loads in solar microgrids introduce power quality issues such as harmonics, voltage distortions, and reduced system efficiency. These disturbances negatively impact the stability and performance of microgrid components, leading to increased losses and potential equipment damage.
Exaud Tweve   +2 more
wiley   +1 more source

PZS‐Net: Incorporating of Frame Sequence and Multi‐Scale Priors for Prostate Zonal Segmentation in Transrectal Ultrasound

open access: yesAdvanced Intelligent Systems, Volume 7, Issue 1, January 2025.
A deep‐learning‐based segmentation method that aimed to segment prostate zones in transrectal ultrasound videos shows results similar to the labels annotated by expert urologists in a prospectively acquired test database. The method is demonstrated to significantly improve prostate zonal segmentation compared with popular segmentation methods.
Jianguo Ju   +5 more
wiley   +1 more source

Self tunning filter for three levels four legs shunt active power filter with fuzzy logic controller

open access: yesActa Polytechnica, 2021
The low harmonic distortion and reduced switching losses are the advantages of using the multilevel inverter. For this purpose, the three-level inverter is used in this paper as a three-phase four-leg shunt active power filter (SAPF). The SAPF is used to
Dahmane Djendaoui   +3 more
doaj   +1 more source

Single-phase shunt active power filter with UPS operation using a bidirectional Dc-Dc converter for energy storage interface [PDF]

open access: yes, 2017
This paper presents a single-phase shunt active power filter (SAPF) with bidirectional dc-dc converter for uninterruptible power supply (UPS) operation.
Afonso, João L.   +4 more
core   +1 more source

Constrained FCS‐MPC‐Based Current Controller for Voltage Source Converters: Application to Shunt Active Power Filters

open access: yesIET Electric Power Applications, Volume 19, Issue 1, January/December 2025.
In this paper, a constrained FCS‐MPC based current controller is introduced for controlling shunt active power filters. In the proposed current controller, the objective function is same as used in the conventional FCS‐MPC and a switching frequency constraint is considered to reduce the average switching frequency. The results obtained from FPGA in the
Shahram Karimi   +4 more
wiley   +1 more source

Unified architecture of single-phase active power filter with battery interface for UPS operation [PDF]

open access: yes, 2017
This paper presents a shunt active power filter with battery interface for uninterruptible power supply (UPS) operation. The proposed unified architecture is composed by a single-phase ac-dc converter from the power grid side and by a bidirectional ...
Afonso, José A.   +4 more
core  

Home - About - Disclaimer - Privacy