Results 51 to 60 of about 2,262 (162)
Effects of phacoemulsification on intraocular pressure and anterior chamber depth
Purpose The aim of this study was to investigate the effects of phacoemulsification and intraocular lens (IOL) implantation, in nonglaucomatous patients with cataract, on intraocular pressure (IOP) and anterior chamber depth (ACD) together with ...
Tarek A Hafez
doaj +1 more source
Ocular changes as potential biomarkers for early diagnosis of Alzheimer's disease
Abstract Alzheimer's disease (AD) is a progressive neurodegenerative disorder and the most common cause of dementia. AD diagnosis often involves a thorough assessment, including clinical evaluation, cognitive testing, medical history examination, genetic testing, and biomarker analysis. Currently, the invasive nature and high costs of biomarker testing,
Purna Chandra Poudel +6 more
wiley +1 more source
Entre los medios diagnósticos que más se han difundido en los últimos años se encuentran los basados en las imágenes de Scheimpflug, como el Pentacam de Oculus Wetzlar de Alemania. Entre sus modelos de evaluación contiene la realización de la paquimetría
Marerneda Domínguez Randulfe +5 more
doaj
Abstract Purpose To provide an overview of artificial tears marketed in the following Nordic countries: Denmark, Finland, Norway, Iceland and Sweden. Furthermore, this review aimed to highlight the different preservatives and other constituents found in artificial tears in the Nordic market, focussing on adverse effects.
K. N. Mikha +9 more
wiley +1 more source
Anterior chamber parameters after laser iridotomy in primary angle-closure spectrum
Aim: To evaluate anteriorchamber parameter after laser iridotomy in primary angle closure disease spectrum. Objectives: To study central anterior chamber depth morphology (CACD) anterior chamber volume (ACV), anterior chamber angle (ACA) in primary angle
B. S. Chetana, Y. M. Manjula
doaj +1 more source
Extremely asymmetric ectasia: Tomographically unilateral keratoconus
Abstract Purpose To investigate the characteristics of apparently stable forms of tomographically unilateral keratoconus (KC). Methods In this retrospective case–control study, strict unilaterality criteria were applied to select tomographically unilateral cases with ≥3 years of follow‐up.
Hasan Shabani +6 more
wiley +1 more source
Inter and intra observer reproducibility of the new Oxford CCD Scheimpflug camera [PDF]
Scheimpflug photography is a well recognised technique for obtaining sagittal views of the anterior structures of the human eye in vivo. A new generation of Scheimpflug camera, which uses a CCD (charge coupled device) instead of film, permitting the digitised image achieved to be directly analysed using computerised linear scanning densitometry, is ...
M L, Harris, G T, Smith, N A, Brown
openaire +2 more sources
Abstract Purpose To evaluate the effect of artificial tear (AT) application on the repeatability of corneal parameters with three different devices. Methods In this prospective, randomized clinical trial, 145 patients were measured with one of three devices in the Department of Ophthalmology, Goethe University, Frankfurt, Germany.
Titus Schug +3 more
wiley +1 more source
Assessing UVA and Laser‐Induced Crosslinking via Brillouin Microscopy
UVA crosslinking is the primary treatment to combat keratoconus. Nevertheless, unwanted side effects and limitations due to nonselective irradiation lead to the investigation of alternative irradiation treatments. This study shows similar changes in the Brillouin frequency shift of corneas crosslinked with UVA irradiation and a NIR femtosecond laser ...
Christian A. Iriarte‐Valdez +8 more
wiley +1 more source
Three-Dimensional Camera Calibration Considering Scheimpflug Condition
Presently, a new calibration scheme for the camera under the Scheimpflug condition is proposed, which represents an exact projection from the object through the lens to the inclined image sensors and also handles the distortion by the lens theoretically.
YOKOYAMA, Hiroshi +2 more
openaire +2 more sources

