Extremely asymmetric ectasia: Tomographically unilateral keratoconus
Abstract Purpose To investigate the characteristics of apparently stable forms of tomographically unilateral keratoconus (KC). Methods In this retrospective case–control study, strict unilaterality criteria were applied to select tomographically unilateral cases with ≥3 years of follow‐up.
Hasan Shabani +6 more
wiley +1 more source
Scheimpflug imaging of the post lens tear film during contact lens wear [PDF]
A new imaging methodology is described to visualise the post lens tear film (PLTF) during contact lens wear. A rotating-Scheimpflug camera in combination with sodium fluorescein allows evaluation of the PLTF for different contact lens modalities,
Vincent, Stephen J. +3 more
core
Abstract Purpose To evaluate the effect of artificial tear (AT) application on the repeatability of corneal parameters with three different devices. Methods In this prospective, randomized clinical trial, 145 patients were measured with one of three devices in the Department of Ophthalmology, Goethe University, Frankfurt, Germany.
Titus Schug +3 more
wiley +1 more source
Assessing UVA and Laser‐Induced Crosslinking via Brillouin Microscopy
UVA crosslinking is the primary treatment to combat keratoconus. Nevertheless, unwanted side effects and limitations due to nonselective irradiation lead to the investigation of alternative irradiation treatments. This study shows similar changes in the Brillouin frequency shift of corneas crosslinked with UVA irradiation and a NIR femtosecond laser ...
Christian A. Iriarte‐Valdez +8 more
wiley +1 more source
Abstract Introduction Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope.
Asif Iqbal +4 more
wiley +1 more source
Influence of brightness artefacts on corneal densitometry
Abstract Purpose To quantify objectively the influence of brightness artefacts inherent in Scheimpflug tomography on corneal densitometry (CD) estimates. Methods Fifty‐seven healthy participants aged 30.9 ± 13.7 years (range 17–60 years) were examined with a Ziemer Galilei G2 Scheimpflug tomographer.
Ana R. Arizcuren +2 more
wiley +1 more source
Measurements of anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter using two Scheimpflug imaging devices [PDF]
Purpose: To compare the ocular anterior chamber depth, white-to-white distance, anterior chamber angle, and pupil diameter, as measured with two different Scheimpflug imaging devices.
Antonio Jesus Del Águila-Carrasco (5763764) +4 more
core +1 more source
International Values of Central Pachymetry in Normal Subjects by Rotating Scheimpflug Camera
In corneal refractive surgery, postoperative ectasia risk assessment routinely includes pachymetric analysis at the apex and thinnest point. We examined whether these data differ worldwide and constructed preliminary country-specific normative thresholds.This was a multicenter, cross-sectional study.Using the Pentacam Eye Scanner (OCULUS GmbH, Wetzlar,
Matthew T, Feng +12 more
openaire +2 more sources
Corneal topographic indices of scheimpflug camera in type 2 diabetic and non-diabetic elderly populations. [PDF]
Hashemi A +4 more
europepmc +1 more source
Comparison of a New Scheimpflug Camera and Swept-Source Optical Coherence Tomographer for Measurements of Anterior Segment Parameters. [PDF]
Huang X +10 more
europepmc +1 more source