Results 21 to 30 of about 496,393 (139)

The liquid-argon scintillation pulseshape in DEAP-3600

open access: yesEuropean Physical Journal C: Particles and Fields, 2020
DEAP-3600 is a liquid-argon scintillation detector looking for dark matter. Scintillation events in the liquid argon (LAr) are registered by 255 photomultiplier tubes (PMTs), and pulseshape discrimination (PSD) is used to suppress electromagnetic ...
DEAP Collaboration   +105 more
doaj   +1 more source

Measurements of the Beam-Wave Fluctuations over a 142-km Atmospheric Path [PDF]

open access: yes, 2006
An optical link has been established between the Canary Islands La Palma and Tenerife. A 1064-nm transmitting laser was located on La Palma whereas a BPSK communication receiver and measurement instruments were installed in ESA's OGS on Tenerife.
Perlot, Nicolas   +11 more
core   +1 more source

Measurement of total scatter factor for stereotactic cones with plastic scintillation detector

open access: yesJournal of Medical Physics, 2017
Advanced radiotherapy modalities such as stereotactic radiosurgery (SRS) and image-guided radiotherapy may employ very small beam apertures for accurate localized high dose to target.
Suresh H Chaudhari   +4 more
doaj   +1 more source

SCINTILLATION DETECTOR [PDF]

open access: yes, 2007
FIELD: gamma- and neutron-radiation detectors. SUBSTANCE: proposed scintillation detector that can be used for detecting sources of neutrons, radioactive and fissionable materials in various radiation monitoring systems has scintillator recording either ...
Marks, Stanislav Viktorovich   +27 more
core   +11 more sources

Development of Large-Area Charged Particle Detector with Inorganic Scintillator Plates and Wavelength Shifting Fibers

open access: yesEPJ Web of Conferences, 2018
A Large-area charged particle detector for highenergy physics experiments has been developed. This detector includes inorganic scintillator plates with thicknesses of 0.5 mm and wavelength-shifting fibers (WLSFs) of 0.2 mm in diameters.
Mizuno Takahiro   +6 more
doaj   +1 more source

Data from multi year and multi radiation detector measurements of different radiation sources with environmental data

open access: yesData in Brief, 2020
The data described consists of radiation measurement outputs from several different detectors located in Abu Dhabi, UAE, for the duration of 30 November 2014 through 13 December 2016.
Braden Goddard   +5 more
doaj   +1 more source

Timing detectors setup prototype for determining EAS axis direction

open access: yesВестник. Серия физическая, 2021
This work presents a prototype setup for determining extensive air showers (EAS) axis direction. The detector system consists of four scintillation detectors (100x100x1 cm) using wavelength-shifted fibers light collection.
O.A. Kalikulov   +9 more
doaj   +1 more source

Design and Simulation of Three-dimensional Position Sensitive Detector with Monolithic Scintillation Crystal Based on Lens Array for Multiple Focus Points

open access: yesYuanzineng kexue jishu
The monolithic scintillation crystal detector has the ability to position the three-dimension interaction location of the gamma ray in the detector depending on accurate acquisition of scintillation light distribution.
LI Ting1,2,3, ZHUANG Kai1,2,3, LI Daowu1,3, LIANG Xiuzuo1,3, LIU Yantao1,3, ZHANG Yiwen1,3, KONG Lingqin1,2,3, ZHANG Zhiming1,2,3,4, SHUAI Lei1,3,4, WEI Long1,2,3,4
doaj   +1 more source

Pulse-shape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

open access: yesEuropean Physical Journal C: Particles and Fields, 2021
The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $$^{39}\text{ Ar }$$ 39 Ar beta decays and is suppressed using pulse-shape ...
P. Adhikari   +128 more
doaj   +1 more source

Influence of various geometries on detection efficiency of polystyrene, polyvinyl-toluene, and sodium iodide detectors using Geant4 [PDF]

open access: yesNuclear Technology and Radiation Protection, 2015
In this work, comparative study on energy dependence of absorbed, intrinsic, photo-peak and absolute total efficiency of polystyrene plastic scintillation fiber and polyvinyl-toluene detectors with NaI(Tl) scintillation detectors has been ...
Mirza Sikander M.   +3 more
doaj   +1 more source