Purpose To report a case of scleral melting following implantation of a Gore-Tex®-sutured scleral-fixated intraocular lens (SFIOL). Methods Single-case report.
Hatem Kalantan +5 more
doaj +1 more source
Background Descemet membrane endothelial keratoplasty is a preferred treatment for endothelial dysfunction, but complications, such as graft detachment and Pseudomonas keratitis, may affect results.
Nir Erdinest +3 more
doaj +1 more source
Imma Gimenez-Sanchis,1 Beatriz Palacios-Carmen,1 Angel García-Garrigós,1 Javier Cantó-Vañó,1 Antonio J Pérez-Ortega,1 David P Piñero2 1Opticas ClaraVisión, Ontinyent, Spain; 2Department of Optics ...
Gimenez-Sanchis I +5 more
doaj
reservedPourpose To compare the surgical outcomes and safety between sutureless scleral fixation intraocular lens (IOLs) (Carlevale®, Soleko, Italy) and 4-point Gore-tex scleral fixated IOLs for secondary implantation in patients with IOL dislocation or ...
POLO, CHIARA
core
Visual outcome following scleral fixated intraocular lens implantation
Introduction: Scleral fixated intraocular lens(SFIOL) implantation to correct aphakia offers superior visual rehabilitation in comparison to aphakic spectacles or contact lens. This study was done to evaluate a simplified technique of scleral fixation of
Aparajita Manoranjan +2 more
core +1 more source
Changes in the Thickness of the Sublens Water Layer in Patients Using Scleral Lenses
Purpose of the study. To analyze the change in the thickness of the sublens water layer depending on the time of wearing lenses in patients using scleral lenses using the SkyOptix Laboratory lenses as an example.Patients and methods.
O. I. Ryabenko +3 more
doaj +1 more source
Gas permeable materials improve the corneal response to scleral lenses [PDF]
Scleral contact lenses are rarely used in modern contact lens practice, and their advantages are generally no longer ...
Carkeet, Nicole +2 more
core
A new lens for observing fundus with a noncontact wide-angle viewing system
Mihori Kita, Yukiko Fujii, Sachiyo Hama Department of Ophthalmology, National Organization Kyoto Medical Center, Kyoto, Japan Abstract: Drying of the cornea during surgery, which causes poor visibility of the fundus, is one of the most serious problems
Kita M, Fujii Y, Hama S
doaj
Survey-Based Estimation of Corneal Complications Associated with Scleral Lens Wear. [PDF]
Schornack MM +5 more
europepmc +1 more source
Scleral Lens Applications Focused on Korean Patients with Various Corneal Disorders. [PDF]
Lee KE +6 more
europepmc +1 more source