Results 191 to 200 of about 598,855 (311)

Multimodal Haptic Perception Through Synergistic Nanocomposite Sensor Arrays

open access: yesAdvanced Materials Technologies, EarlyView.
Multi‐modal fingertip haptics are advanced through a bioinspired &vertical‐via' electronic skin architecture. A confined PDMS/MWCNT/NiNP nanocomposite, sitting at the percolation threshold, enables tactile, thermal, and magnetic sensing. A unique via‐density gradient and dedicated &Un‐Touch' reference nodes provide robust spatial resolution and signal ...
Amos Bardea, Fernando Patolsky
wiley   +1 more source

The CES-D Questionnaire, A Self Report Depression Scale

open access: yes, 1977
This questionnaire taps the degree to which people are currently experiencing depression. This survey was developed by researchers at the Centers for Disease Control and has been used extensively on large projects for several years.
Centers for Disease Control
core  

Aluminum Oxynitride‐Engineered Transparent Aluminum Nitride Resistive Memory for Low‐Leakage Multilevel Switching in Micro‐LED Pixels

open access: yesAdvanced Materials Technologies, EarlyView.
An AlON interfacial layer is engineered within an AlN switching layer to enable transparent RRAM with four stable resistance states. The device achieves low‐voltage multilevel switching and a high HRS, allowing precise grayscale modulation and preventing light leakage in micro‐LEDs operated at VDD = 2.7 V.
Sung Keun Choi   +7 more
wiley   +1 more source

Upcycling Compact Discs Into Ultra‐Stable, Flexible, and Stretchable Nanoporous Gold Electrodes for Enhanced Biosensing Performance

open access: yesAdvanced Materials Technologies, EarlyView.
This article highlights the development of robust and high‐performance flexible and stretchable biosensors that maintain long‐term functionality and optimal electrical conductivity under mechanical deformation, utilizing sustainable and cost‐effective manufacturing principles.
Mousa H. Aldosari, Ahyeon Koh
wiley   +1 more source

On‐Chip Saturated Absorption of CO2 in a Silicon‐on‐Sapphire Waveguide

open access: yesAdvanced Optical Materials, EarlyView.
We demonstrate the first saturated absorption of a molecular gas on a planar photonic chip. By coupling carbon dioxide with the tightly confined light of a silicon‐on‐sapphire waveguide, we achieve optical saturation using only milliwatt powers. This breakthrough provides a practical, low‐power foundation for creating ultra‐compact mid‐infrared ...
Shahar Edelstein   +2 more
wiley   +1 more source

Soft Robotic Excretory Care Simulator for Nursing Education: Functional and Perceptual Biomimetics Approach

open access: yesAdvanced Robotics Research, EarlyView.
A soft robotic simulator is developed to replicate the digital removal of feces (DRF), a sensitive yet essential nursing procedure. Integrating soft actuators, sensors, and a realistic rectal model, the simulator balances functional fidelity with perceptual realism. Engineering evaluations and nurse feedback confirm its potential to enhance training in
Shoko Miyagawa   +10 more
wiley   +1 more source

Home - About - Disclaimer - Privacy