Study of neutron sensitivity for vanadium self-powered neutron detector in nuclear reactors
Vanadium self-powered neutron detectors (SPNDs) are widely used as in-core unmovable detectors in nuclear power plants to continuously carry out data monitoring of neutron flux and nuclear power.
Xiong Wu +4 more
doaj +3 more sources
Advances in High-Temperature Irradiation-Resistant Neutron Detectors [PDF]
To achieve a substantial enhancement in thermodynamic efficiency, Generation IV nuclear reactors are designed to operate at significantly elevated temperatures compared to conventional reactors.
Chunyuan Wang +3 more
doaj +2 more sources
Self Powered Neutron Detectors with High Energy Sensitivity [PDF]
Fiore S. +8 more
doaj +2 more sources
Diagnostics of in-core neutron monitoring system based on artificial neural network
One of the tasks of the diagnostics of in-core neutron control is the task of diagnostics of self-powered neutron detectors, namely the determination of reliability of self-powered neutron detectors signal, that is, the detection of the fault self ...
Володимир Іванович Борисенко +2 more
doaj +5 more sources
NMDB@Home 2020: Proceedings of the 1st virtual symposium on cosmic ray studies with neutron detectors [PDF]
With the Proceedings of the 1st virtual symposium on cosmic ray studies with neutron detectors launches the new open access series Cosmic ray studies with neutron detectors.
core +1 more source
Design of High-Gain Signal Amplifier Circuit for Prompt-Response Self-Powered Neutron Detector [PDF]
Self-Powered neutron detectors (SPND) detect current generated from interaction of neutron flux with emitter materials. They are inside a reactor in NPP (Nuclear Power Plant), and currently used to monitor the output and control the operation.
Heejune Park +2 more
doaj +1 more source
Sorted compressive sensing for reconstruction of failed in-core detector signals
Self-Powered Neutron Detectors(SPNDs) are used to calculate core power distributions, an essential factor in the safe operation of nuclear power plants. Some detectors may fail during normal operation, and signals from failed detectors are isolated from ...
Gyu-ri Bae +3 more
doaj +1 more source
MONACO v2: Multipurpose and Integrated Data Acquisition System for On-line Neutron and Gamma Measurements [PDF]
The CEA MONACO v2 a multichannel acquisition system dedicated to neutron and gamma measurements. It is unique as it integrates all the following features in one module: automatic generation of saturation curves, automatic generation of pulse ...
Barbot L. +6 more
doaj +1 more source
These investigation findings prove the possibility of a engineering solution for VVER core automatic protection during operation in both nominal and transient conditions within ICIS using local parameters (i.e. linear heat power of the most stressed fuel
Lys Stepan, Kanyuka Alexandr
doaj +1 more source
Estimation of the maximum linear heat rate using soft computing techniques: a case study of Bushehr Nuclear Power Plant [PDF]
This study uses real data of Bushehr nuclear power plant (BNPP), and by soft computing methods and without using the data of self-powered neutron detectors (SPNDs), the maximum linear heat rate of BNPP is estimated.
S. Sharifi +2 more
doaj +1 more source

