Results 131 to 140 of about 226,009 (332)
Chronic Disease Monitoring Using Advanced Compliant Materials for Bioelectronics
Compliant bioelectronic systems enable continuous monitoring of chronic disease through soft, stretchable materials and tissue‐conformal designs that support stable electrophysiological, mechanical, and biochemical sensing. Integration of diverse sensing modalities with thoughtful material selection, device architectures, and advanced fabrication ...
Han Kim +7 more
wiley +1 more source
Self‐Adhesive Conductive Elastomers for Gel‐Free Biopotential Recording
σPOMaC, a self‐adhesive conductive citrate elastomer incorporating PEDOT:PSS and DBSA, enables gel‐free biopotential electrodes with stable conductivity and intrinsic skin adhesion. The composite exhibits low resistivity (∼ 0.02 Ω·cm), robust electrical performance during repeated use, and reliable on‐body ECG acquisition comparable to Ag/AgCl ...
Kirstie M. K. Queener +7 more
wiley +1 more source
This study evaluated the structural safety of 9 greenhouse types under extreme weather loads using a nonlinear finite element method (FEM) model that accounts for material nonlinearity of clamp joint.
Byung-Hun Seo +7 more
doaj +1 more source
Emerging Materials and Future Strategies for Solid Oxide Electrochemical Cells
Solid oxide electrochemical cells operate under strongly coupled electrochemical and thermodynamic conditions, where performance is constrained by interactions among crystal structure, defect chemistry, and interfacial evolution. This review, based on a structure‐defect‐property‐durability framework, reveals the roles of lattice symmetry and defect ...
Qiuchun Lu +4 more
wiley +1 more source
Parametric Study on Mechanical Behavior of Beam–Column Joint with L-Shaped Components
This paper introduces a beam–column joint with an L-shaped component formed by combining two traditional semi-rigid connection methods, namely top and bottom angle steel connections and end-plate connections.
Yuanyuan Xia +3 more
doaj +1 more source
Optimal design of frame structures with semi-rigid joints
In this paper, a genetic algorithm is proposed for discrete minimal weight design of steel planar frames with semi-rigid beam-to-column connections. The frame elements are constructed from a predetermined range of section profiles. Conventionally, the analysis of frame structures is based on the assumption that all connections are either frictionless ...
openaire +2 more sources
ELASTO-PLASTIC BUCKLING ANALYSIS OF A SEMI-RIGIDLY JOINTED RETICULAR DOME WITH INITIAL IMPERFECTIONS
Hideyuki Takashima, Shiro Kato
openalex +2 more sources
Flexible tactile sensors have considerable potential for broad application in healthcare monitoring, human–machine interfaces, and bioinspired robotics. This review explores recent progress in device design, performance optimization, and intelligent applications. It highlights how AI algorithms enhance environmental adaptability and perception accuracy
Siyuan Wang +3 more
wiley +1 more source
Design of Bionic Knee Joint Mechanism based on Tensegrity Structure
On the basis of the locomotion mechanism and biological characteristic of the human knee joint,a structural mapping model of bionic knee joint mechanism is established through equivalent mapping and bionic design method which is based on a C4S2 plane ...
Wei Zhang, Lin Liu, Guangsheng Song
doaj
Stability and P-Δ Analysis of Generalized Frames with Movable Semi-Rigid Joints [PDF]
Byoung Cheol Min
openalex +1 more source