Results 51 to 60 of about 421,096 (303)
Effective Calibration of Low-Cost Soil Water Content Sensors
Soil water content is a key variable for understanding and modelling ecohydrological processes. Low-cost electromagnetic sensors are increasingly being used to characterize the spatio-temporal dynamics of soil water content, despite the reduced accuracy ...
Heye Reemt Bogena +4 more
doaj +1 more source
ATF4‐mediated stress response as a therapeutic vulnerability in chordoma
We screened 5 chordoma cell lines against 100+ inhibitors of epigenetic and metabolic pathways and kinases and identified halofuginone, a tRNA synthetase inhibitor. Mechanistically halofuginone induces an integrated stress response, with eIF2alpha phosphorylation, activation of ATF4 and its target genes CHOP, ASNS, INHBE leading to cell death ...
Lucia Cottone +11 more
wiley +1 more source
Application of Configuration Software and Modbus Agreement in Mine-used Sensor Calibration Device
In view of problems of no functions of real-time data display and processing, automatic closed-loop control and communication interface of current sensor calibration devices, the paper put forward a method of applying configuration software and Modbus ...
XING Qian, TIAN Mu-qin, WANG Xue-song
doaj
Visual-inertial self-calibration on informative motion segments
Environmental conditions and external effects, such as shocks, have a significant impact on the calibration parameters of visual-inertial sensor systems. Thus long-term operation of these systems cannot fully rely on factory calibration.
Burri, Michael +5 more
core +1 more source
Peroxidasin enables melanoma immune escape by inhibiting natural killer cell cytotoxicity
Peroxidasin (PXDN) is secreted by melanoma cells and binds the NK cell receptor NKG2D, thereby suppressing NK cell activation and cytotoxicity. PXDN depletion restores NKG2D signaling and enables effective NK cell–mediated melanoma killing. These findings identify PXDN as a previously unrecognized immune evasion factor and a potential target to improve
Hsu‐Min Sung +17 more
wiley +1 more source
Volumetric Calibration Refinement using masked back projection and image correlation superposition [PDF]
This paper deals with a new, reconstruction based, approach of refining a volumetric calibration. The technique is based on a 2D cross-correlation between particle images on the sensor plane with a planar back projection from a tomographic reconstruction
Bruecker, C., Hess, D., Watz, B.
core
Induction of diabetes in three different mouse strains uniformly resulted in an increase in TNAP activity and a reduction in pyrophosphate (PPi) in the circulation. Inhibition of TNAP restored plasma PPi. Diabetes‐induced calcification in the media layer of the aorta was detected only in the Abcc6−/− strain, which is predisposed to ectopic ...
Krisztina Fülöp +13 more
wiley +1 more source
This research protocol outlines a workflow for nuclear magnetic resonance (NMR)‐based metabolomics in the agri‐food sector. Using two case studies—strawberry leaves (solid matrix) and wine (liquid matrix)—it details the procedures for sample preparation, data acquisition, and processing.
Andrea Fernández‐Veloso +4 more
wiley +1 more source
Measurement System for the Calibration of Accelerometer Arrays
This paper addresses accelerometer array calibration, focusing on determining the errors between multiple sensors. Micro-electromechanical system (MEMS) based triaxial accelerometers, key components of Inertial Measurement Units (IMUs), are ...
Richárd Pesti +3 more
doaj +1 more source
Attitude ground support system for the solar maximum mission spacecraft [PDF]
The SMM attitude ground support system (AGSS) supports the acquisition of spacecraft roll attitude reference, performs the in-flight calibration of the attitude sensor complement, supports onboard control autonomy via onboard computer data base updates ...
Nair, G.
core +1 more source

