Influence of machine topology and cross-coupling magnetic saturation on rotor position estimation accuracy in extended back-EMF based sensorless PM brushless AC drives [PDF]
The influence of the machine topology and dq-axis cross-coupling on the rotor position estimation error in an extended back-EMF based sensorless brushless AC drive is investigated by both finite element analysis and experimentally on four brushless AC ...
Bingham, Chris +4 more
core +1 more source
Sensorless speed control of DC motor using EKF estimator and TSK fuzzy logic controller
In this article, sensorless speed control of DC motor has been proposed using the extended Kalman filter (EKF) estimator and Takagi–Sugeno-Kang (TSK) fuzzy logic controller (FLC).
Ravi Pratap Tripathi +3 more
doaj +1 more source
PMSM design optimization concerning sensorless performance and torque ripple
This paper proposes a multi objective design optimization approach concerning sensorless performance and torque ripple for Permanent Magnet Synchronous Machine.
Haiteng Sun +4 more
doaj +1 more source
Cross-Saturation Effects in IPM Motors and Related Impact on Sensorless Control [PDF]
Permanent-magnet-assisted synchronous reluctance motors are well suited to zero-speed sensorless control because of their inherently salient behavior. However, the cross-saturation effect can lead to large errors on the position estimate, which is based ...
Guglielmi, Paolo +2 more
core +2 more sources
An implementation of rotor speed observer for sensorless induction motor drive in case of machine parameter uncertainty [PDF]
The paper describes observers using model reference adaptive system for sensorless induction motor drive with the pulse width modulator and the direct torque control under the circumstances of incorrect information of induction motor parameters.
Brandštetter, Pavel +3 more
core +3 more sources
Improved signal injection based sensorless technique for PM brushless AC drives [PDF]
The accuracy of rotor position estimation in the conventional signal injection based sensorless control of permanent magnet brushless AC drives depends on the load current.
Bingham, Chris +3 more
core +1 more source
Position estimation delays in signal injection-based sensorless PMSM drives [PDF]
The causes of position estimation delays and their effects on the sensorless control of permanent magnet synchronous motor drives are investigated. The position of a permanent magnet synchronous machine is estimated via the injection of high frequency ...
Altomare, A. +3 more
core +1 more source
Improved rotor position estimation in extended back-EMF based sensorless PM brushless AC drives with magnetic saliency [PDF]
An improved extended back-EMF based sensorless control method is proposed for a brushless AC motor equipped with an interior permanent magnet rotor. It accounts for dq-axis cross-coupling magnetic saturation by introducing an apparent mutual winding ...
Bingham, Chris, Howe, D, Li, Y, Zhu, Z Q
core +1 more source
Application of Sensorless Control Technology of Permanent Magnet Synchronous Motor in Tianjin Metro
The necessity of sensorless control technology of permanent magnet traction system in the field of rail transit was introduced, the position estimation method based on the electromagnetic relation of permanent magnet motor was summarized, and the ...
Xingxiang ZHOU
doaj
MRAS Based Sensorless and Sensor Vector Control and Smooth Transient Between Them
Dynamic control, like vector control is an essential feature of every modern AC drive. In some cases it might be very important to provide continuous operation in case of encoder failure.
Jakub Vonkomer, Milan Zalman