Results 211 to 220 of about 18,045 (263)
Some of the next articles are maybe not open access.

Transformer Tap Setting in Optimal Load Flow

IEEE Power Engineering Review, 1985
A new method of transformer ratio control in optimal load flow is presented. The transformer taps and the phase shift angles can be controlled by a quite general criterion function. The method established is valid both for two-and three-winding transformers.
N. Flatabo, J.A. Foosnas, T.-o. Berntsen
openaire   +1 more source

Use of Tap Water and Disinfection Practices in Outpatient Settings: A Survey of Otolaryngologists

Archives of Otolaryngology - Head and Neck Surgery, 1991
A survey of otolaryngologists belonging to the American Academy of Otolaryngology-Head and Neck Surgery was conducted to estimate the frequency of tap water use during otologic examinations and to assess methods used for disinfection of otologic instruments in outpatient settings. Questionnaires were returned by 516 persons residing in 49 states.
P W, Lowry, W R, Jarvis
openaire   +2 more sources

Substation-oriented PMU placement considering transformer tap settings

2018 IEEE International Conference on High Voltage Engineering and Application (ICHVE), 2018
The most crucial functions of modern power systems are monitoring and control. These tasks can be efficiently accomplished using synchronized phasor measurement units (PMUs) which are extremely accurate devices installed at substations providing measurements of the voltage phasor at the installation bus and the current phasors in the branches ...
Nikolaos M. Manousakis, George N. Korres
openaire   +1 more source

Optimal tap settings for voltage regulation transformers in distribution networks

2013 North American Power Symposium (NAPS), 2013
In this paper, we propose a method to optimally set the taps of voltage regulation transformers in distribution networks. Specifically, we cast the problem of optimally choosing the tap settings as a rank-constrained semidefinite program (SDP) with the transformer tap positions removed from the network's admittance matrix and replaced by additional ...
Brett A. Robbins   +2 more
openaire   +1 more source

Can Personal Goal Setting Tap the Potential of the Gifted Underachiever?

Roeper Review, 2010
Although underachieving gifted students have been largely ignored in empirical research, there has been a modest surge of interest in describing and “treating” this population in recent years. It is estimated that nearly half of gifted youth achieve significantly below their potential.
Dominique Morisano, Bruce M. Shore
openaire   +1 more source

Optimization of fixed tap transformer setting in bulk electric systems

IEEE Transactions on Power Systems, 1991
A novel technique was developed to determine fixed tap transformer settings that are optimal for several load patterns representing, for example, winter peak, summer peak, and off-peak loading patterns. The solution algorithm is based on the Newton approach and employs a recently developed technique to identify binding inequality constraints. A special
W. Kellerman   +3 more
openaire   +1 more source

Refugees set to tap demand for virtual workforce

New Scientist, 2009
Crowd-sourcing may help spread the benefits of the digital economy to previously excluded ...
openaire   +1 more source

Optimising Low-Voltage Transformer Tap Settings in Distribution Networks

2019 29th Australasian Universities Power Engineering Conference (AUPEC), 2019
In this paper, a practical method of determining the optimal tap setting of no-load distribution tap-changing transformers is proposed. The uptake of distributed energy resources impacts the risk of distribution systems violating voltage constraints.
Joshua Paoli   +2 more
openaire   +1 more source

On-load tap changer's dynamic resistance measurement: Settings and interpretation

2011 Electrical Insulation Conference (EIC)., 2011
An on-load tap changer (OLTC) is prone to many different defects and degradation mechanisms due to its continuous operation under load condition. A high load current and high operation temperature accelerate the process of contact wear. Contacts erode due to the fact that under certain conditions the contacts develop a resistive layer due to hot ...
J. J. Erbrink   +5 more
openaire   +1 more source

Observability and estimation of transformer tap setting with minimal PMU placement

2008 IEEE Power and Energy Society General Meeting - Conversion and Delivery of Electrical Energy in the 21st Century, 2008
One of the most important applications of phasor measurement units (PMUs) is power system state estimation. Some models have been proposed for including phasor measurements in the state estimation. But, all of these models have treated transformer tap settings (voltage transformer turns ratio and phase-shift transformer angle) as fixed parameters of ...
M. Shiroie, S. H. Hosseini
openaire   +1 more source

Home - About - Disclaimer - Privacy