Results 121 to 130 of about 25,194 (239)
Optical Sensing of SF6 Dissociation Levels in Electrical Discharges [PDF]
Sulphur hexafluoride (SF6) is widely used as an insulating medium in high voltage systems including switchgear, transformers and transmission lines.
Hyde, Graham +3 more
core
Electron swarm and transport coefficients for the binary mixtures of SF6 with Ar and Xe
A pulsed Townsend technique was used to measure the electron drift velocity, the longitudinal diffusion, and the effective ionization coefficients, and the limiting field strength for the binary mixtures of SF6 with Ar and Xe.
de Urquijo, J +7 more
core +1 more source
Performance Evaluation of a Commercial-Scale Sulfur Hexafluoride (SF6) Thermal Destruction Process
Recently, the importance of carbon neutrality has been highlighted, and the power industry is also making efforts to reduce the use of SF6, which is mainly used in power facilities.
Mi-Yeong Kim +4 more
doaj +1 more source
通过应用SF6红外成像检漏仪与SF6定量检漏仪进行模拟、对比试验,对SF6红外成像检漏的检测灵敏度进行量化研究,同时研究了风速、温度等外部因素对检测灵敏度的影响情况,对SF6红外成像检漏仪与SF6定量检漏仪的现场使用经验进行了有益的探索。
胡连清 +4 more
doaj
Analyse of SF6 Properties in High-Voltage Equipments and its Optimal Utilization with Combination N2
The fundamental characteristics and properties of SF6 and its mixtures with N2 and CO2 are given. Current wave-forms of initial stages of negative corona discharge formation in a short negative point-to-plane gap have been measured with nanosecond time ...
Jozef Kudelcik, Miroslav Gutten
doaj
Viscosity of SF6+N2 and SF6+He gaseous mixtures.
TANAKA, YOSHIYUKI +3 more
openaire +2 more sources
Negative ions as charge carriers in gaseous detectors: Results in Xe, SF6 and Xe-SF6 mixtures
In this paper, we characterize Xe, SF6 and Xe-SF6 mixtures as detection media in gas detectors. In particular, given the nature of SF6, the goal is to explore the advantages that may derive from thisfeature. The study, which assessed electron attachment
Marques, A.P. +5 more
core +1 more source
机械式SF6密度控制器在运行中时有误报警现象。对国内外已使用过的4类SF6密度控制器的不同结构、SF6温度、环温以及使用处海拔高度对监控特性的影响进行了分析。得出,Ⅳ型国产密度控制器质量稳定、监控精度较好;目前使用的SF6密度控制器对GCB/GIS的SF6密度具有一定的监控作用,但不能避免开关运行时出现的SF6密度示数"假高"现象,为消除密度示数"假高"、对环境温度的欠补偿和海拔影响,根本出路是开发新型智能化的SF6密度控制器。
黎斌
doaj
Detection and Capture of Volatile Fluorinated Compounds Using Porous Materials. [PDF]
Hou J +7 more
europepmc +1 more source
Realizations of the triple points of carbon dioxide and sulfur hexafluoride-ITS-90 temperature determinations and interpolations. [PDF]
Quelhas KN, Wang RS, Peruzzi A, Tew WL.
europepmc +1 more source