Results 131 to 140 of about 81,247 (279)
Micro Partial Discharge Characteristics of SF6 Under DC Voltage
ABSTRACT In gas‐insulated high‐voltage direct current (HVDC) devices, micro partial discharges (PD) caused by micro‐protrusions or surface roughness on conductors or enclosures may not cause immediate insulation system failure due to their weak discharge intensity.
Geng Chen +4 more
wiley +1 more source
ABSTRACT Large‐capacity generator circuit breaker (GCB) based on vacuum interrupter technology is the key power equipment to ensure the safe operation of the power system. When the short‐circuit current was forced to cross zero, the large‐capacity GCB was difficult to generate a zero‐voltage environment through freewheeling, the vacuum interrupter (VI)
Xiangyu Han +8 more
wiley +1 more source
Josephson junctions with centered step and local variation of critical current density
Superconductor-insulator-ferromagnet-superconductor (SIFS) Josephson tunnel junctions based on Nb\Al2O3\Ni\Cu\Nb stacks with a thickness step in the metallic NiCu interlayer were fabricated.
Weides, M.
core +1 more source
Development of ± 550 kV DC GIS Basin Insulator
ABSTRACT The basin insulator is a core component of the insulation system for ± 550 kV gas‐insulated switchgear (GIS). This paper, using a finite element method for multi‐physics simulations of electric–thermal coupling, determines a geometry suitable for the industrial production of ± 550 kV GIS basin insulators.
Shaohua Cao +9 more
wiley +1 more source
Anisotropy in Dry‐Type Valve‐Side Bushings of Converter Transformer: Phenomena and Effects
ABSTRACT The safe and stable working of dry‐type valve‐side bushings, important components of converter transformers, is essential. In recent years, poor design has led to several core breakdown, flashover and cracking failures. The bushing cores, composed of crepe paper and aluminium foil, exhibit significant anisotropic physical properties due to its
Gaoyi Shang +6 more
wiley +1 more source
通过应用SF6红外成像检漏仪与SF6定量检漏仪进行模拟、对比试验,对SF6红外成像检漏的检测灵敏度进行量化研究,同时研究了风速、温度等外部因素对检测灵敏度的影响情况,对SF6红外成像检漏仪与SF6定量检漏仪的现场使用经验进行了有益的探索。
胡连清 +4 more
doaj
The growing environmental challenge of electrical energy systems has prompted a substantial increase in renewable energy generation. Such generation systems allow for significant reduction of CO2 emissions compared with a traditional fossil fuel plant ...
A. Beroual, A. Haddad
semanticscholar +1 more source
ABSTRACT As a commonly used bushing current‐carrying structure in recent years, contactor‐type electrical connection parts operate in a complex environment of electric, thermal and chemical corrosion for extended periods. With the increase of ultra‐high voltage (UHV) transmission capacity, its operating environment faces more stringent challenges, and ...
Qingyu Wang +9 more
wiley +1 more source
Reform of 220 kV GIS SF6 Pressure Protectio
The paper introduced general situation of GIS SF6 pressure protection,analyzed problems of design defect and faulty start existed in GIS SF6, discussed reform necessity.Taking bus-tie switch 2245 as example, it put forward a reform scheme used PLC for ...
MENG Xiang-xi
doaj
This work focused on arowana fishes (Teleostei, Osteoglossiformes) as a model; their widespread intercontinental distribution and basal phylogenetic position within Teleostei make them a compelling model for evolutionary research, especially in the realm of satDNA molecular evolution. Through the integration of genomic and chromosomal data, we analyzed
Fernando Henrique Santos de Souza +9 more
wiley +1 more source