Results 191 to 200 of about 25,194 (239)
Some of the next articles are maybe not open access.
Transport properties of F− in SF6–Xe, SF6–Ar and SF6–He mixtures
2012no ...
Benhenni, Malika, Yousfi, Mohammed
openaire +1 more source
Volume electrical discharge in Ne/SF6/C6H14 and pure SF6
Russian Physics Journal, 1999The electrical and spatial characteristics of a volume electrical discharge are studied as functions of the ratio of partial pressures of the mixture components at varying initial voltage. Early in the discharge, hot (plasma) cathode spots are observed with diffusive plasma flares developing above them.
Yu. I. Bychkov +2 more
openaire +1 more source
Infrared intensities in crystalline SF6
Spectrochimica Acta, 1962Abstract Absolute infrared intensities of solid SF 6 have been measured. The results are v 5 , B = 104,000 cm mmole −1 v 6 , B = 12,200 cm mmole −1 The values represent a 1 per cent decrease and 63 per cent increase, respectively, from the gas phase.
D DOWS, G WIEDER
openaire +1 more source
Chemical Physics Letters, 1995
Abstract The gas-phase clustering reactions of SF 5 − , SF 6 − and F − ions with SF 6 were measured using a high-pressure mass spectrometer. The bond energies of SF 5 − (SF 6 ) 1 and SF 6 − (SF 6 ) 1 were estimated to be ⩽2.3 kcal/mol. The bond energies of F − (SF 6 ) n with n = 1 and 2 were determined to be 5.4 and ≈4.1 kcal/mol ...
Kenzo Hiraoka +5 more
openaire +1 more source
Abstract The gas-phase clustering reactions of SF 5 − , SF 6 − and F − ions with SF 6 were measured using a high-pressure mass spectrometer. The bond energies of SF 5 − (SF 6 ) 1 and SF 6 − (SF 6 ) 1 were estimated to be ⩽2.3 kcal/mol. The bond energies of F − (SF 6 ) n with n = 1 and 2 were determined to be 5.4 and ≈4.1 kcal/mol ...
Kenzo Hiraoka +5 more
openaire +1 more source
Mobility Estimates of SF6 − Ion in Parent SF6 Gas
2004In high-voltage transmission systems and plasma technology it is of primary interest to understand various aspects of corona discharge phenomenon leading to corona stability regime in non-uniform gaps filled with high-pressure SF6 gas. This invokes determination of swarm parameters for modeling kinetic behavior of ions and ionic clusters.
Celal Korasli, Vedat Karsli
openaire +1 more source
Ionization, Attachment and Breakdown in SF6
Nature, 1970SULPHUR hexafluoride is widely used as an insulator in many electrical devices, but little is known of its fundamental electrical properties, particularly at voltages above about 100 kV. As the first part of an investigation on the growth of pre-breakdown ionization in SF6, we have carried out measurements from which values of the apparent primary ...
J, Dutton, F M, Harris, G J, Jones
openaire +2 more sources
[Infrared spectrum analysis of SF6 and SF6 decomposition].
Guang pu xue yu guang pu fen xi = Guang pu, 2015Pressured SF6 gas is widely used in GIS for electrical insulation as well as for are extinction. And a chemical way for detecting the SF6 and its byproducts is a powerful diagnosis method for GIS. The present paper analyzes the decomposition of insulated gas of GIS (mostly SF6) in three cases with infrared spectrometer.
Tao, Cai +3 more
openaire +1 more source
Breakdown Strength of N2-SF6 Gas Mixtures Containing 10% and 5% SF6 Compared with pure SF6
2001SF6 as insulating gas has a very good dielectric strength. Therefore, SF6 is used in many applications. Nowadays, it is investigated again whether SF6-N2 mixtures can replace pure SF6 in for example gas-insulated substations and lines. For pure SF6 the optimal gas pressure varies between 4 and 6 bar.
Sander Meijer +2 more
openaire +1 more source
On the replacement of SF6 by air in internal arc testing of MV SF6 insulated switchgear
IET Conference Publications, 2009Internal arc tests are intended to verify the effectiveness of switchgear design in protecting personnel in case of an internal arc. With the IEC 62271-200 & 201 in 2003, new methods and criteria for testing metal/insulation enclosed switchgear under conditions of an internal arc have been formulated.
Smeets, R.P.P. +7 more
openaire +2 more sources
Study of the arc interruption performance of SF6-CO2 mixtures as a substitute for SF6
IEEE Transactions on Dielectrics and Electrical Insulation, 2016CO2 attracts a lot of attention of researchers as a possible substitute for SF6. The arc interruption capabilities of SF6-CO2 mixtures for different mixed ratios are investigated in this paper by carrying out tests with a 126 kV puffer gas circuit breaker prototype and calculations. Based on the measured arc voltage and current around current zero, the
Hu Zhao +5 more
openaire +1 more source

