Results 201 to 210 of about 3,563,944 (406)

Risk analysis of the Unity 1.5T MR‐Linac adapt‐to‐shape workflow

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background and Purpose The adapt‐to‐shape (ATS) workflow on the Unity MR‐Linac (Elekta AB, Stockholm, Sweden) allows for full replanning including recontouring and reoptimization5. Additional complexity to this workflow is added when the adaptation involves the use of MIM Maestro (MIM Software, Cleveland, OH) software in conjunction with ...
Jiayi Liang   +13 more
wiley   +1 more source

Evaluating feature extraction reproducibility across image biomarker standardization initiative‐compliant radiomics platforms using a digital phantom

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Background The aim of this study was to thoroughly analyze the reproducibility of radiomics feature extraction across three Image Biomarker Standardization Initiative (IBSI)‐compliant platforms using a digital phantom for benchmarking. It uncovers high consistency among common features while also pointing out the necessity for standardization ...
Han‐Back Shin   +5 more
wiley   +1 more source

Shared Decision Making

open access: bronze, 2002
Robert E. McKeown   +3 more
openalex   +1 more source

Advantages and limitations of navigation‐based multicriteria optimization (MCO) in selectively sparing pharyngeal constrictor muscles in head and neck radiotherapy treatment planning

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose Sparing pharyngeal constrictor muscles (PCMs) during radiotherapy improves patient‐reported swallowing function. This study aimed to explore the feasibility of integrating knowledge‐based planning (KBP) with multicriteria optimization (MCO) in Eclipse v18.0 to selectively spare PCM, quantify the required trade‐off in prophylactic ...
Laura K. Howard   +3 more
wiley   +1 more source

Medical Students, Clinical Preventive Services, and Shared Decision-Making

open access: bronze, 2002
Carole Keefe   +2 more
openalex   +1 more source

Enhanced analysis of gating latency in 0.35T MR‐linac through innovative time synchronization of a motion phantom and plastic scintillation detector

open access: yesJournal of Applied Clinical Medical Physics, EarlyView.
Abstract Purpose This study aims to evaluate how different gantry angles, breathing rates (BPM), cine image speeds, and tracking algorithms affect beam on/off latency and the subsequent impact on target dose for a 0.35T MR‐Linac with a 6 MV FFF beam.
Mateb Al Khalifa   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy