Results 181 to 190 of about 1,925,346 (295)
ABSTRACT Electronic waste has emerged as a major environmental challenge, driven by the massive consumption and a limited lifetime of modern electronic devices, stimulating the development of sustainable electronics. Here, an all‐biomaterial gelatin‐choline‐citric acid ([Ch][CA]) ionogel is developed as an active binder to realize self‐sintered ...
Lin Guo +10 more
wiley +1 more source
Fatal traumatic injury patterns in free-roaming cats: an anatomopathological study of 40 cases. [PDF]
Sampaio RAG +8 more
europepmc +1 more source
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang +7 more
wiley +1 more source
My bad tooth and why it matters: the neglected value of "Medical Touch". [PDF]
Schattner A.
europepmc +1 more source
In situ Auger Electron Spectroscopy resolves oxidation states with high fidelity during the pulsed laser deposition of multivalent perovskite manganate and vanadate heterostructures. The chemical‐state signature is carried by the valence‐electron population of the transition‐metal cation, read out through the relative intensities of Auger fine ...
Harish Kumarasubramanian +1 more
wiley +1 more source
Healthcare Waste Management Practices and Facilitators and Barriers in Primary Healthcare Facilities: A Mixed-Methods Study in Kathmandu, Nepal. [PDF]
Magar KT +3 more
europepmc +1 more source
Omnipolar Magnetic Field Detection by Superlattice‐Based Hall Sensor
Magnetic‐field‐induced electronic switching is demonstrated in unit‐cell‐engineered La0.7Sr0.3MnO3–BiFeO3 superlattices. Distinct substrate terminations modify magnetic and transport properties. Hall resistance measurements show omnipolar, hysteretic anomalous Hall switching above the Curie temperature, arising from Fe─Mn interfacial exchange, enabling
Mark Huijben +6 more
wiley +1 more source
Integrity of Tumor Tissue Collected by Ultrasonic Aspirator: A Cellular and Molecular Perspective. [PDF]
Maldonado J +11 more
europepmc +1 more source
Ferroelectric tunnel junction devices based on epitaxial undoped ferroelectric HfO2 films demonstrate stable switching endurance of over 106 switching cycles, low write voltages of ±3 V, 16 measured resistance states, and neuromorphic capability.
Markus Hellenbrand +13 more
wiley +1 more source

