Results 41 to 50 of about 422,398 (302)
As one of the key main equipment of the power system, the transformer directly affects the safe and reliable operation of the system. In the process of transformer reclosing, the internal electromagnetic environment is obviously different from that of ...
Yuefeng Hao +3 more
doaj +1 more source
To improve the accuracy of fault location system, several short-circuit tests need to be conducted before being brought into service in autotransformer (AT) feeding systems for high-speed railways in China.
Qing-an Ma, Wei Liu
doaj +1 more source
Like the widely-used semiconductor switch, Insulated Gate Bipolar Transistors (IGBTs) are subject to many failures and degradation in power electronic converters.
Sadegh Mohsenzade +2 more
doaj +1 more source
Thyristor based short circuit current injection in isolated grids [PDF]
This paper proposes a thyristor based short circuit current injector for providing short circuit current in isolated and weak grids, where sufficient fault current to trigger circuit breakers may not be available.
Hoff, Bjarte +5 more
core +1 more source
Intratumour heterogeneity complicates precision management of advanced endometrial cancer. Circulating tumor DNA (ctDNA) offers a minimally invasive strategy to capture tumor evolution and therapeutic resistance. Here, we compare tumor‐agnostic NGS with tumor‐informed ddPCR, outlining their relative sensitivity, concordance, and clinical implications ...
Carlos Casas‐Arozamena +15 more
wiley +1 more source
A short-circuit protection circuit is proposed for power electronic systems employing silicon carbide metal–oxide–semiconductor field-effect transistors.
Seungjik Lee +5 more
doaj +1 more source
Features of fault transient's in generator network of powerful electric power stations
THE PURPOSE. To consider the problems of generator circuit breaker. To consider the problems of high degree of asymmetry of short-circuit current and long delayed current zeros in detail. Propose methods for solving these problems. Develop the equivalent
E. P. Safonov, V. Ya. Frolov
doaj +1 more source
In this study, a fault diagnosis model based on magnetic density is proposed to analyse the current characteristics of synchronous generator rotor inter‐turn short circuit and air gap eccentric single fault and composite fault.
He, Yu‐Ling +6 more
core +1 more source
Acute caffeine treatment protects the developing retina from ischemia‐induced cell death
Caffeine reduces cell death in the developing retina under ischemia (OGD). This effect does not involve BDNF upregulation or antioxidant pathways (NRF2/VEGF). Neuroprotection occurs mainly through adenosine A2A receptor antagonism, decreasing glutamate release and excitotoxicity, highlighting caffeine's potential as an acute neuroprotective agent in ...
Amanda Alves Nascimento +6 more
wiley +1 more source
High Speed Level Converters With Short Circuit Current Reduction
The level converter is used as interface between low voltages to high voltage boundary. The efficient level converter has less power consumption and less delay are the design considerations of the level shifter.
Avireni Srinivasulu +1 more
doaj +1 more source