Results 71 to 80 of about 181,213 (309)

Investigation on Stator Winding Inter-turns Short Circuit Fault Diagnosis

open access: yesJournal of Harbin University of Science and Technology, 2018
On the basis of negative sequence current generation mechanism analysis of synchronous generator stator winding inter-turns short circuit,the method of detecting and diagnosing synchronous generator stator winding inter-turns short circuit is proposed ...
ZHAO Hong-sen   +4 more
doaj   +1 more source

Planar Solid‐State Nanopores Toward Scalable Nanofluidic Integration Based on CMOS Technology

open access: yesAdvanced Engineering Materials, EarlyView.
We present a scalable silicon‐based fabrication strategy for planar solid‐state nanopores to enable their integration with complex nanofluidic systems. Prototype devices demonstrate normal voltage‐current characteristics, good noise performance, and appreciable streaming currents. Our CMOS‐compatible fabrication process offers precise geometric control
Ngan Hoang Pham   +7 more
wiley   +1 more source

A Study of Symmetrical and Unsymmetrical Short Circuit Fault Analyses in Power Systems

open access: yesSakarya Üniversitesi Fen Bilimleri Enstitüsü Dergisi, 2019
In this study, thecommon symmetrical and unsymmetrical short circuit faults in power systems areanalyzed detailed. Unlike the similar studies in the literature, metallic faultconditions for unsymmetrical faults are also given in the paper additionally ...
Yılmaz Yıldırım, Faruk Yalçın
doaj   +1 more source

Analisis Kerja Rele Overall Differential Pada Generator Unit I PLTA Ketenger PT Indonesia Power UBP Mrica [PDF]

open access: yes, 2010
Plant has two important equipment that are the generator and transformer. Therefore, it should be protected well by the overall differential relay. This relay must be reliable from the disturbances that might arise.
Prasetijo, H. (Hari)   +1 more
core   +3 more sources

Short Circuit Fault Detection and Protection of DC Microgrid

open access: yesInternational Journal for Research in Applied Science and Engineering Technology, 2023
Abstract: Due to inherent advantages of DC system over AC system such as compatibility with renewableenergy sources, storage devices and modern loads, Direct Current Microgrid (DCMG) has been one of the key research areas from last few years. In the proposed work power has been produced by using solar pv and fuel cell which is combined on the same dc ...
Nikhil Sonule, Prof. Vaishali Madekar
openaire   +1 more source

Dynamic Testing of Cold Gas Sprayed Bipolar Plates–Porous Transport Layer Coating System in Proton Exchange Membrane Water Electrolysis

open access: yesAdvanced Engineering Materials, EarlyView.
Through direct application of porous transport layer (PTL) on the bipolar plate (BPP) with thermal spraying, the interfacial contact resistance is improved. With the cold gas sprayed BPP–PTL coating system, a proton exchange membrane water electrolysis cell with a cell voltage of Ucell = 1.9 V can be operated up to i = 2.5 A/cm2 in a dynamic mode ...
Kirsten Bobzin   +5 more
wiley   +1 more source

Analysis of vertical strip wound fault-tolerant permanent magnet synchronous machines [PDF]

open access: yes, 2013
This paper investigates the behavior of a vector- controlled, fault-tolerant, permanent magnet motor drive system adopting a vertically placed strip winding (VSW) which can limit inter-turn short-circuit (SC) fault current to its rated value regardless ...
Arumugam, Puvaneswaran   +3 more
core   +1 more source

Copper Nanocrystallization in Anodic Oxide Films of Ti–Cu‐Based Bulk Metallic Glass and Its Effect on the Corrosion Resistance and Cytocompatibility

open access: yesAdvanced Engineering Materials, EarlyView.
Viktoriia Shtefan, Thorgund Nemec, Ute Hempel, Annett Gebert and coworkers demonstrate that anodic treatment of Ti–Cu‐based metallic glass in a nontoxic pyrophosphate electrolyte forms a protective bilayered Ti/Zr‐oxide film enriched with Cu nanocrystals.
Viktoriia Shtefan   +8 more
wiley   +1 more source

Analysis of interturn short circuit in regulating winding of power transformer based on field-circuit coupling

open access: yesFrontiers in Energy Research
The interturn short circuit fault is one of the common faults in power transformers. At present, research on interturn short circuit faults focuses on high, medium, and low voltage windings, while there is relatively little research on interturn short ...
Liangchang Fei   +7 more
doaj   +1 more source

A Fault Tolerant Machine Drive Based on Permanent Magnet Assisted Synchronous Reluctance Machine [PDF]

open access: yes, 2016
A fault tolerant machine drive based on permanent magnet assisted synchronous reluctance machine (PMA SynRM) is proposed and investigated for applications where reliability and safety are crucial.
Chong, E.   +5 more
core   +2 more sources

Home - About - Disclaimer - Privacy