Results 81 to 90 of about 31,830 (307)
The adjustable speed hydro-generating unit has a complex three-phase alternating current excitation structure. The existing rotor winding short circuit (RWSC) fault diagnosis methods are generally difficult to use to locate the fault location and ...
Jian Qiao +6 more
doaj +1 more source
Operational control and protection implications of fault current limitation in distribution networks
Rising short-circuit fault current levels is one of the problems associated with the increased presence of distributed generation (DG) in electrical networks.
Blair, S.M. +3 more
core
Contribuição à deteção de defeitos nos rotores de turboalternadores [PDF]
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Elétrica.Este trabalho tem como objetivo desenvolver métodos de detecção, localização e caracterização de defeitos em um ...
Tanno Iamamura, Bruno Akihiro +1 more
core
Field‐free spin‐orbit torque domain‐wall synapses integrated with stochastic MTJ neurons enable compact hardware Boltzmann machines. Leveraging intrinsic stochasticity and multi‐level conductance, the system achieves efficient probabilistic learning with high accuracy, demonstrating a scalable spintronic platform for energy‐efficient edge AI.
Aijaz H. Lone +8 more
wiley +1 more source
Historical Foundation and Practical Guideline for Ferroelectric Switching Kinetic Studies
The P and U pulses in the conventional PUND measurements are not identical because of the interplay between switching current and the measurement circuit components. This circuit effect can lead to a shift in polarization transients and misinterpreted physics in the switching kinetics.
Yi Liang, Pat Kezer, John T. Heron
wiley +1 more source
The problem of distinguishing and classifying the responses of analog integrated circuits containing catastrophic faults has aroused recent interest. The problem is made more difficult when parametric variations are taken into account. Hence, statistical
Chalk, C D +7 more
core +1 more source
Variation aware analysis of bridging fault testing [PDF]
This paper investigates the impact of process variation on test quality with regard to resistive bridging faults. The input logic threshold voltage and gate drive strength parameters are analyzed regarding their process variation induced influence on ...
Ingelsson, Urban +5 more
core +1 more source
Tuning Separator Chemistry: Improving Zn Anode Compatibility via Functionalized Chitin Nanofibers
Nanochitin derived from waste shrimp shells is used to fabricate separators for aqueous zinc batteries. By tuning the density of amine and carboxylic surface groups, water mobility at the separator interface is controlled, promoting uniform zinc deposition, suppressing dendrite growth, and enabling exceptional cycling stability exceeding 2000 h ...
Ibrahim Al Kathemi +6 more
wiley +1 more source
Motor current signature analysis (MCSA) is a common practice in industry for finding motor faults. However, because of small modulations caused by faults and high noise contamination, it is difficult to quantify the modulation in measured signals which ...
Gu, Fengshou +8 more
core
A growing number of designs of future Unmanned Aerial Vehicle (UAV) applications utilise dc for the primary power distribution method. Such systems typically employ large numbers of power electronic converters as interfaces for novel loads and generators.
Burt, Graeme +7 more
core +1 more source

