Results 91 to 100 of about 159,486 (302)

Simultaneous Enhancement of Open-Circuit Voltage, Short-Circuit Current Density, and Fill Factor in Polymer Solar Cells

open access: yes, 2011
Simultaneous enhancement of open-circuit voltage, short-circuit current density, and fill factor in highly efficient polymer solar cells by incorporating an alcohol/water-soluble conjugated polymer as cathode interlayer is domonstrated.
Chen, LW (陈立桅)   +7 more
core  

Regulated Ion‐Diffusion Hydrogels for Subtle and Multimodal Temperature‐Strain Sensing in Wound Monitoring

open access: yesAdvanced Functional Materials, EarlyView.
A soft, dual‐channel hydrogel patch enables simultaneous detection of wound temperature and strain by integrating ion‐diffusion‐mediated thermoelectric and resistive sensing. The conformal design maintains stable performance during motion, capturing subtle inflammatory and mechanical changes for continuous wound monitoring.
Yu Fang   +7 more
wiley   +1 more source

Research and Optimization of High-voltage IGBT Module Short CircuitCharacteristics for Traction Application

open access: yes机车电传动, 2014
Three IGBT short circuit types had been introduced. The short circuit type 2 had been enhanced through optimization of theIGBT transistor gain to withstand higher short circuit current.
LIU Guo-you   +5 more
doaj  

Operational control and protection implications of fault current limitation in distribution networks

open access: yes, 2009
Rising short-circuit fault current levels is one of the problems associated with the increased presence of distributed generation (DG) in electrical networks.
Blair, S.M.   +3 more
core  

Multimodal Soft Surgical Robots Enabled by Eco‐Degradable, Sterilizable Polymers and Transient Electronics

open access: yesAdvanced Functional Materials, EarlyView.
A compostable PGS soft surgical robot with interchangeable modules integrates transient Mo tactile and Si thermal sensors for dual feedback. The device preserves its function after clinical‐grade sterilization, demonstrates stable actuation and cardiac tissue grasping with real‐time in vivo pulsatile monitoring, and biodegrades post‐use with soil‐safe, 
Minseong Chae   +27 more
wiley   +1 more source

Arc root mobility on piezoelectrically actuated contacts in miniature circuit breakers [PDF]

open access: yes, 2005
A novel contact opening mechanism has been developed using a piezoelectric actuator to open the contacts in a low contact opening velocity circuit breaker.
Weaver, P.M.   +5 more
core   +1 more source

Omnipolar Magnetic Field Detection by Superlattice‐Based Hall Sensor

open access: yesAdvanced Functional Materials, EarlyView.
Magnetic‐field‐induced electronic switching is demonstrated in unit‐cell‐engineered La0.7Sr0.3MnO3–BiFeO3 superlattices. Distinct substrate terminations modify magnetic and transport properties. Hall resistance measurements show omnipolar, hysteretic anomalous Hall switching above the Curie temperature, arising from Fe─Mn interfacial exchange, enabling
Mark Huijben   +6 more
wiley   +1 more source

Investigation on Stator Winding Inter-turns Short Circuit Fault Diagnosis

open access: yesJournal of Harbin University of Science and Technology, 2018
On the basis of negative sequence current generation mechanism analysis of synchronous generator stator winding inter-turns short circuit,the method of detecting and diagnosing synchronous generator stator winding inter-turns short circuit is proposed ...
ZHAO Hong-sen   +4 more
doaj   +1 more source

Magnetic flux analysis in superconducting Fault Current Limiters under short-circuit conditions

open access: yes, 2012
In order to obtain a more compact Superconducting Fault Current limiter (SFCL), a special geometry of core and AC coil is required. This results in a unique magnetic flux pattern which differs from those associated with conventional round core ...
Darmann, Frank   +9 more
core   +1 more source

Detection and Diagnosis of Motor Stator Faults using Electric Signals from Variable Speed Drives [PDF]

open access: yes, 2015
Motor current signature analysis has been investigated widely for diagnosing faults of induction motors. However, most of these studies are based on open loop drives.
Shaeboub, Abdulkarim   +9 more
core   +1 more source

Home - About - Disclaimer - Privacy