Results 11 to 20 of about 159,486 (302)
Large number of photovoltaic (PV) power plants connected to a power grid can bring significant impacts to fault currents and the operation of protection systems.
Shuai Yuan +2 more
doaj +1 more source
The existing zero-crossing point prediction algorithms of short-circuit current have some problems, such as complex calculation and big error. For three-phase short-circuit fault of coal mine power supply system, a zero-crossing point prediction ...
YU Shuohang +3 more
doaj +1 more source
The energetics of gas flow and contact erosion during short circuit arcing [PDF]
The processes governing the movement of short circuit arcs in circuit breakers are complex and variable and the detailed understanding of these processes is incomplete.
Weaver, P.M. +2 more
core +1 more source
In this study, genetic programming (GP) is used for optimizing bus and line separation methods to reduce the short-circuit current. Expanding power systems led to intensive electric power and more transmission lines, reducing the grid impedance.
Dabin Son, Sangwook Han
doaj +1 more source
Characteristics of Short-Circuit Current in Distribution Network with Doubly-Fed Wind Power System
The doubly-fed induction generator (DFIG) is connected to the distribution network as a distributed power source, which turns a radial single power supply system into a dual power supply system and changes the topology of the distribution network. When a
XI Xinze, XING Chao, QIN Risheng, HE Tingyi, HE Peng, MENG Xian, CHENG Chunhui
doaj +1 more source
A change-detection algorithm for short-circuit fault detection in closed-loop AC drives [PDF]
This paper deals with an on-line method for turn-to-turn short-circuit fault detection in low-voltage permanent-magnet synchronous machine drives. Due to the closed-loop control, the fault effects are reflected in the voltage.
Johan Gyselinck +10 more
core +1 more source
Optical fiber imaging for high speed plasma motion diagnostics: applied to low voltage circuit breakers [PDF]
An integrated portable measurement system is described for the study of high speed and high temperature unsteady plasma flows such as those found in the vicinity of high current switching arcs.
Tribulato, G. +9 more
core +1 more source
This paper focuses on determining the effects of short-circuit current values on the operation of high-voltage substations. The analyses performed focused on the dynamic and thermal effects on the short-circuit current for different input data ...
Łukasz Kozarek +11 more
doaj +1 more source
Analysis of short-circuit transients in the LHC main dipole circuit [PDF]
After the occurrence and detection of a short circuit to ground in the LHC main dipole circuit, a fast power abort is triggered and the current in the circuit starts decaying semi-exponentially from a maximum value of 11.85 kA to zero, with a time ...
Maciejewski, M +21 more
core +1 more source
Arc motion and gas flow in current limiting circuit breakers operating with a low contact switching velocity [PDF]
Arc motion in low voltage (240 VAC) high current (10/sup 3/-10/sup 4/A.) current limiting-circuit breakers is dominated by arc root mobility. The mobility is influenced by the gas flow and gas composition in the contact region, but there is little ...
Weaver, P.M. +2 more
core +1 more source

