Results 261 to 270 of about 872,445 (297)
Some of the next articles are maybe not open access.
Short-Circuit Currents of Synchronous Machines
Transactions of the American Institute of Electrical Engineers, 1925The importance of short-circuit forces in large alternators has warranted an investigation of them. The first step in this investigation, which is discussed in this paper, is the calculation of the short-circuit currents that produce them. The method of solution used is that of the assumption of zero resistance and constant flux linkages which has ...
openaire +1 more source
Short-circuit currents and recovery voltages
Electrical Engineering, 1949FIELD tests were made on a 7,200/12,470Y-volt multigrounded rural distribution system to check fault current calculations and to investigate transient recovery voltages experienced as a consequence of clearing fault currents. Tests were also made using a miniature circuit representation of a rural distribution system in order to investigate the effect ...
W. H. Eason +3 more
openaire +1 more source
Effects of short-circuit currents
2005Calculation methods for the thermal and electromagnetic effects of short-circuit currents are dealt with IEC 61660-2, which is applicable to short-circuit currents in d.c. auxiliary installations in power plants and substations and IEC 60865-1, related to three-phase a.c. systems.
openaire +1 more source
Calculation of short-circuit currents
2011The current that flows through an element of a power system is a parameter that can be used to detect faults, given the large increase in current flow when a short-circuit occurs. For this reason, a review of the concepts and procedures for calculating fault currents will be made in this chapter, together with some calculations illustrating the methods
openaire +1 more source
The short-circuited fluxgate output current
Journal of Physics E: Scientific Instruments, 1989The alternative coupling of short-circuiting the secondary coil of a fluxgate sensor by connecting it to the inverting input of a current amplifier is shown to have significant advantages over the more conventional unloaded or second-harmonic tuned voltage coupling.
F Primdahl +3 more
openaire +1 more source
Limitation of short-circuit currents
2005The expansion of electrical power systems by new power stations and new lines (overhead transmission lines and cable circuits) results in an increase of short-circuit currents due to an increase in sources feeding the short-circuit and due to a reduction of system impedance. The improvement of existing installations and the replacement of equipment are
openaire +1 more source
Current-Zero Characteristics of a Vacuum Circuit Breaker at Short-Circuit Current Interruption
2006 International Symposium on Discharges and Electrical Insulation in Vacuum, 2006High resolution measurements on the post-arc current in vacuum circuit breakers reveal a period, immediately following current-zero, in which the voltage remains practically zero. The most widely used model for simulating the interaction between the post-arc current with the electrical circuit lacks a proper explanation for this event, and hence it ...
E. P. A. van Lanen +3 more
openaire +1 more source
Factors for the calculation of short-circuit currents
2005Several factors for the calculation of short-circuit (s.-c.) currents have been introduced in previous sections, the origin of which will be explained within this section. · Voltage factor cmax and cmin for different voltage levels as per Table 4.1. · Correction factor using the %/MVA or the p.u.-system as mentioned in Chapter 2. · Impedance correction
openaire +1 more source
Short-circuit current ratings of equipment
49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference, 2013The interrupting rating and short-circuit current rating of equipment is an key consideration for the installation of equipment in electrical distribution systems. To emphasize this consideration, the 2005 National Electrical Code (NEC®) added short-circuit current rating marking requirements for various types of equipment, that previously was not ...
openaire +1 more source