Results 1 to 10 of about 5,636 (164)

Shunt Active Filter in Damping Harmonics Propagation

open access: yesAdvances in Electrical and Computer Engineering, 2010
This paper deals with a hybrid shunt active power filter applied on 500 kV HVDC, after a description of the causes and effects harmonic pollution which may damage equipments and interrupt electric power customers service; in this paper we present the ...
BERBAOUI, B.   +3 more
doaj   +2 more sources

LCL Interface Filter Design for Shunt Active Power Filters

open access: yesAdvances in Electrical and Computer Engineering, 2010
This paper is focused on finding the parameters of a second order interface filter connected between the power system and the shunt active filter based on switching frequency of the active filter.
DOBRICEANU, M.   +3 more
doaj   +2 more sources

Instrumentation for Verification of Shunt Active Power Filter Algorithms

open access: yesSensors, 2023
This article presents a comprehensive system for testing and verifying shunt active power filter control methods. The aim of this experimental platform is to provide tools to a user to objectively compare the individual control methods. The functionality
Jan Baros   +6 more
doaj   +4 more sources

Shunt Active Filter Controlled by Fuzzy Logic

open access: yesJournal of King Saud University: Engineering Sciences, 2006
Harmonics contamination is a serious and a harmful problem in electric power systems. Active power filtering constitutes one of the most effective proposed solutions.
Hocine Benalla, Hind Djeghloud
doaj   +2 more sources

Power quality improvement by using photovoltaic based shunt active harmonic filter with Z-source inverter converter

open access: yesElectrical engineering & Electromechanics, 2022
Introduction. The major source of energy for a long time has been fossil fuels, however this has its drawbacks because of their scarcity, exhaustibility, and impossibility of reusing them.
B. V. Sai Thrinath   +2 more
doaj   +1 more source

Parallel Association of Shunt Active Power Filters [PDF]

open access: yes2007 IEEE International Symposium on Industrial Electronics, 2007
This paper describes different types of parallel association of Shunt Active Power Filters, presents computer simulation models developed in PSCAD®/EMTDC?, and shows simulated results for each case. The control system used in the active filters is based on the Instantaneous Reactive Power Theory (p-q Theory). The active filters use periodic sampling as
Pregitzer, Ricardo G.   +3 more
openaire   +2 more sources

Review of Fundamental Active Current Extraction Techniques for SAPF

open access: yesSensors, 2022
The field of advanced digital signal processing methods is one of the fastest developing scientific and technical disciplines, and is important in the field of Shunt Active Power Filter control methods.
Jan Baros   +6 more
doaj   +1 more source

A Review of Control Technique Applied in Shunt Active Power Filter (SAPF) [PDF]

open access: yesEngineering and Technology Journal, 2022
In recent years, electronic transformers and electronic devices (nonlinear loads) have increased. These loads are the source of harmonics (non-sinusoidal and distorted waves) and the interactive force that affects the performance of the power system ...
Ayad Hadi, Ekhlas Thjeel, Ali Nahar
doaj   +1 more source

Sliding mode controller for four leg shunt active power filter to eliminating zero sequence current, compensating harmonics and reactive power with fixed switching frequency [PDF]

open access: yesSerbian Journal of Electrical Engineering, 2015
In this paper, the four leg inverter controlled by the three dimensional space vector modulation (3D SVM) is used as the shunt active power filter (SAPF) for compensating the three phase four wire electrical network, by using the four leg ...
Chebabhi Ali   +3 more
doaj   +1 more source

Three-Phase Shunt Active Power Filter [PDF]

open access: yesAmerican Journal of Applied Sciences, 2008
Active power filters have been widely used for harmonic elimination. The performance of a conventional three-phase shunt Active Power Filter (APF) using Synchronous Detection Method (SDM) has been compared with Nonlinear Autoregressive-Moving Average (NARMA)-L2 based APF. The novelty of this study lies in the application of NARMA-L2 control to generate
Moleykutty George, Kartik Prasad Basu
openaire   +1 more source

Home - About - Disclaimer - Privacy