Results 31 to 40 of about 5,636 (164)

Active power filter with enhanced echo state network in radar power supply system

open access: yesIET Power Electronics, 2023
There have been concerns raised on load non‐linearity as more and more load types are being introduced into the radar power supply system. The non‐linear load produces harmonic current while it seriously threatens the normal and safe operation ...
Zongguo Tao   +5 more
doaj   +1 more source

Line-Interactive UPS as Shunt Active Power Filter

open access: yes2019 International Conference on Electrical Drives & Power Electronics (EDPE), 2019
This paper describes a newly proposed solution for using the line-interactive uninterruptible power supply (UPS) system as a shunt active power filter. An overview of active power filters topologies and control strategies for active power filters are presented. The proposed solution is compared to similar solutions.
Šunde, Viktor   +2 more
openaire   +2 more sources

Shunt Active Parallel Filter, Grid Photovoltaic System

open access: yesWSEAS TRANSACTIONS ON POWER SYSTEMS, 2023
This paper introduces a study focused on managing a photovoltaic system connected to the electrical grid. The primary components of this system include solar arrays linked via a DC bus to an inverter situated on the grid side. Fluctuations in solar irradiance and temperature are swift, prompting the integration of maximum power point tracking (MPPT ...
Achwak Alazrag   +2 more
openaire   +1 more source

Power Quality Improvement with Three-Phase Shunt Active Power Filter Prototype Based on Harmonic Component Separation Method with Low-Pass Filter

open access: yesEnergies
This work contributes to both Romania’s and the European Union’s energy policies by highlighting the research results obtained within the Dunarea de Jos University of Galati, but also through the technological transfer of this knowledge to the industry ...
Marian Gaiceanu   +3 more
doaj   +1 more source

Performance Investigation of Grid-Connected DFIG using Integrated Shunt Active Filtering Capabilities [PDF]

open access: yesE3S Web of Conferences, 2020
This paper presents the modified grid side converter control (GSC) technique which enable the GSC to work as a shunt active filter to mitigate the grid current harmonics produced by the nonlinear load, as well as to transfer power from the grid to the ...
Patel Krishna S., Makwana Vijay H.
doaj   +1 more source

Adaptive filter based current controller for Shunt Active filter

open access: yesInternational Journal of Engineering & Technology, 2018
This paper deals with the harmonic mitigation and reactive power compensation using Shunt Active filter. The performance of the Shunt active filter depends on the design and current control technique for generating a reference current. The design of the filter involves the iterative procedure for choosing the filter components so that it compensates ...
R Sriranjani, S Jayalalitha
openaire   +2 more sources

An efficient harmonic detection approach for shunt active filter based on wavelet transform

open access: yesAin Shams Engineering Journal, 2018
This paper described with the harmonics detection and compensation in power system. The two accepted and impressive methods in noise and harmonic detection field are implemented in this present work.
Indu Maurya, S.K. Gupta, Priyanka Maurya
doaj   +1 more source

An improved three-level shunt active filter [PDF]

open access: yes1998 International Conference on Power Electronic Drives and Energy Systems for Industrial Growth, 1998. Proceedings., 2005
A shunt active filter is capable of removing harmonic currents from the supply of commercial and industrial sites. This paper presents a novel method for generating the compensating current signal for an active filter that uses a three-level inverter to provide a fast transient response.
S. Round, H. Laird, R. Duke, C. Tuck
openaire   +1 more source

Hybrid optimization shunt active power filter based on radar power system

open access: yesMeasurement + Control, 2023
The problem of load nonlinearity is exposed as more and more load types are introduced into the radar power system. The nonlinear load is easy to produce large harmonic current, but at the same time it seriously threatens the normal and safe operation of
Yuetong Wang   +6 more
doaj   +1 more source

Comparison Analysis of Shunt Active Filter and Transformerless Parallel Hybrid Active Filter

open access: yesComputer Science & Information Technology ( CS & IT ), 2013
This research work presents the comparison analysis of Shunt Active Filter (SAF) with Parallel Hybrid Active Filter (PHAF). The performances of SAF and PHAF have been analyzed with PI controllers based on Synchronous Reference Frame theory. In each case, simulation is carried out for three phase unbalanced non liner load conditions.
Sakshi Bangia, Sharma P.R, Maneesha Garg
openaire   +1 more source