Results 41 to 50 of about 5,636 (164)

Fuzzy Controller with Shunt Active Power Filter in Reducing THD for Three Phase System

open access: yesInternational Transactions on Electrical Engineering and Computer Science
In recent years, power electronics devices have advanced and are now employed in a variety of applications. Furthermore, this gadget produced an issue with power quality in the electrical system.
K. Hemasri, Ch. Srinivasa Kumar
doaj   +3 more sources

Detection Algorithm For Active Filters Based On Adaptive Inverse Control

open access: yesJournal of Applied Science and Engineering, 2023
In order to accurately compensate the harmonics and reactive power of the active power filter, a paralleltype active filter detection algorithm based on adaptive inverse control is proposed to control and follow the DC capacitor voltage, obtain the ...
Longhai Fu
doaj   +1 more source

SIL Modeling of Shunt Harmonics Active Filter

open access: yes, 2020
The evolution in semiconducting devices has introduced flexible control on a system but it has also penetrated harmonics in the grid, which results in extra electrical stress and load. Limiting the presence of harmonics in the grid and low power factor maintained by consumers has become of utmost priority to the power system analyst.
Dhiman, Shweta, Gupta, A., Chandle, J.
openaire   +2 more sources

An Enhanced Shunt Active Filter Based on Synchronverter Concept

open access: yesIEEE Journal of Emerging and Selected Topics in Power Electronics, 2022
This article proposes a shunt active filter (SAF) operating as a Synchronverter to enhance its performance, including the virtual inertia functionality. The SAF behaves as a voltage source with a low-impedance path for harmonic contents. Synchronverter behavior is used together with selective filtering through proportional-resonant controllers to ...
Bruno Wanderley Franca   +5 more
openaire   +4 more sources

A New Soft-Switched Three-Phase Four-Wire Shunt Active Power Filter [PDF]

open access: yesJournal of Intelligent Procedures in Electrical Technology, 2010
This paper presents a new soft switched topology for losses reduction in a three-phase four-wire shunt active power filter (SAPF). The soft-switching technique not only offers a reduction in switching loss and thermal requirement, but also allows the ...
Mohammad Reza Moradian   +2 more
doaj  

Switching Pattern Improvement for One-Cycle Zero-Integral-Error Current Controller

open access: yesIEEE Access, 2022
The one-cycle current control is a non-linear technique based on the cycle-by-cycle calculation of the ON time of the power converter switches. Its application is not common in tracking fast-changing reference currents, due to the necessity of fast and ...
S. Orts-Grau   +6 more
doaj   +1 more source

New Topology of a Hybrid, Three-Phase, Four-Wire Shunt Active Power Filter

open access: yesEnergies, 2023
With a view to reducing harmonic content in electrical power systems, and, consequently, improving power quality level, filters and other harmonic compensation devices are widely used.
Stefani Freitas   +5 more
doaj   +1 more source

AN ADAPTIVE HARMONIC COMPENSATION STRATEGY FOR THREE-PHASE SHUNT ACTIVE POWER FILTER BASED ON DOUBLE SECOND-ORDER GENERALIZED INTEGRATOR WITH PREFILTER

open access: yesElectrical engineering & Electromechanics, 2020
. This study presents a straightforward adaptive prefiltering algorithm based on a double second-order generalized integrator with prefilter to solve one of the power quality issues, this algorithm is in charge of the determination of the reference ...
S. Kalkoul   +3 more
doaj   +1 more source

Enhanced FPGA-Based Controller for Three Phase Shunt Active Power Filter

open access: yesPower Electronics and Drives, 2023
In this paper, a three-phase shunt active power filter (SAPF) controller with a fully digital implementation is presented. The main goal of this contribution is to implement a digital direct power control (DDPC) algorithm without phase-locked-loop (PLL ...
Benhamadouche Abdelouahab Djoubair   +4 more
doaj   +1 more source

Shunt Active Power Filter with Dynamic Output Current Limitation [PDF]

open access: yes2007 IEEE International Symposium on Industrial Electronics, 2007
This paper presents a shunt active filter with a controller able to dynamically limit the output current, which allows an effective protection of the inverter semiconductors without diminishing the active filter performance. The control strategy is based on the p-q theory expanded for three-phase four-wire systems and the power stage of the active ...
Pregitzer, Ricardo G.   +3 more
openaire   +2 more sources

Home - About - Disclaimer - Privacy