Results 51 to 60 of about 5,636 (164)
Effect of Line Impedance on the Stability of Shunt Active Power Filter Based on LCL Filter
When shunt active power filter based on LCL filter is used for voltage source type harmonic source, the line and load impedances will not only cause the harmonic amplification but also the stability problem based on current tracking.
REN Lei, YUN Pingping
doaj
Comparative Study between Shunt Active Filter and Hybrid Filter
This paper presents an comparative study between shunt active filter and shunt hybrid filter based on configuration system and harmonic isolation. The harmonic isolator isbased on Self Tuning Filters (STF) (it can be tuned at any frequency). The study of the active filter control is divided in two parts.
openaire +1 more source
Model Predictive Current Control for Low-Cost Shunt Active Power Filter
Performance of a three-phase shunt active power filter (SAPF) relies on the capability of the controller to track the reference current. Therefore, designing an accurate current controller is crucial to guarantee satisfactory SAPF operation.
Ali A. Abdel-Aziz +2 more
doaj +1 more source
Hysteresis Control for Shunt Active Power Filter under Unbalanced Three-Phase Load Conditions
This paper focuses on a four-wire shunt active power filter (APF) control scheme proposed to improve the performance of the APF. This filter is used to compensate harmonic distortion in three-phase four-wire systems.
Z. Chelli +3 more
doaj +1 more source
Reduction of source current harmonics in ANN controlled induction motor
Harmonics generated by the nonlinear loads is a serious concern to the power system engineers as it adversely affects the power quality of the system. Recently, many findings focus on reducing the harmonics by introducing various topologies of the filter
A. Sivakumar, N.B. Muthu Selvan
doaj +1 more source
Compensation of active filter using p-q theory in photovoltaic systems
This work proposes an active shunt filter design for grid-connected solar systems, utilizing the p-q instantaneous power theory technique to minimize grid harmonics and reduce reactive power. As a result, the total harmonic distortion (THD) is decreased,
Farzane Soleimani Rudi +1 more
doaj +1 more source
The interactions between shunt active power filter (APF) and capacitance load tend to result in stability problems and resonance. The conventional model of a shunt APF is not precise enough to reflect this phenomenon. To address it, this paper proposes a
Yuqi Bing +6 more
doaj +1 more source
This work proposes an efficient integration method of solar energy with industrial nonlinear loads, accounting for dynamic variations in solar power and load harmonic profiles.
P. Mahesh Reddy +2 more
doaj +1 more source
Robust Harmonic Elimination Method for Various Load Conditions
The present study implements a Direct Power Control (DPC) strategy to manage a photovoltaic (PV) system functioning as a shunt active power filter (shunt APF), aimed at providing reactive power compensation and mitigating harmonic currents while ...
Zakaria Reguieg +3 more
doaj +1 more source
This research proposes a novel method that combines Proportional-Integral (PI) control, Artificial Neural Networks (ANNs), and Synchronous Reference Frame (SRF) theory to improve the performance of a three-phase shunt Active Power Filter (APF) under ...
N. Madhuri, M. Surya Kalavathi