Results 71 to 80 of about 32,587 (211)

Unified architecture of single-phase active power filter with battery interface for UPS operation [PDF]

open access: yes, 2017
This paper presents a shunt active power filter with battery interface for uninterruptible power supply (UPS) operation. The proposed unified architecture is composed by a single-phase ac-dc converter from the power grid side and by a bidirectional ...
Afonso, José A.   +4 more
core  

Comparison of different optimization criteria for optimal sizing of hybrid active power filters parameters [PDF]

open access: yes, 2014
Praise Worthy Prize granted a permission for Brunel University London to archive this article in BURA.Harmonic distortion in power systems has increased considerably due to the increasing use of nonlinear loads in industrial firms and elsewhere.
Elmathana, KTM, Zobaa, AF
core   +1 more source

A PV powered shunt active power filter for power quality improvement

open access: yesGlobal Energy Interconnection, 2019
This paper deals with power quality improvement using a three-phase active power filter (APF) connected to a PV power system. A direct power control (DPC) approach is proposed to eliminate harmonic current caused by any nonlinear loads and at the same ...
Ayoub Benzahia   +5 more
doaj   +1 more source

Three-Level Topology for Shunt Active Power Filters

open access: yesIOP Conference Series: Materials Science and Engineering, 2020
Abstract The development in the field of power electronics has led to its optimum and efficient use in domestic and industrial arena especially in control and automation processes. In turn this has created a threat in terms of power quality issues.
S.P. Richard   +2 more
openaire   +1 more source

Control of a three-phase four-wire shunt-active power filter based on DC-bus energy regulation [PDF]

open access: yes, 2008
This paper presents a nonconventional three-phase four-wire shunt active power filter (APF) topology controlled by using an energy approach. A general study of power terms involved in the operation of the four-wire APF is conducted in order to evidence ...
Blaabjerg, Frede   +4 more
core   +2 more sources

Design of a Measuring System for Electricity Quality Monitoring within the SMART Street Lighting Test Polygon: Pilot Study on Adaptive Current Control Strategy for Three-Phase Shunt Active Power Filters

open access: yesSensors, 2020
This study focuses on the design of a measuring system for monitoring the power quality within the SMART street lighting test polygon at university campuses with relation to testing an adaptive current control strategy for three-phase shunt active power ...
Radek Martinek   +8 more
doaj   +1 more source

Three Phase Shunt Active Power Filter Using Simulink

open access: yesInternational Journal of Scientific Research in Science, Engineering and Technology, 2021
In AC power grids for harmonic emission reduction and reactive power compensation, activity filters have become very common. The network with non-linear loads such as power converters is equipped with an active power filter for optimizing THD. Shunt type or series type. It also enhances voltage control and unbalance in flicks.
openaire   +1 more source

Power Angle Control Scheme for Integration of UPQC in Grid Connected PV System [PDF]

open access: yes, 2015
The quality of electric power is greatly affected by the proliferation of non-linear loads in electrical energy processing applications like switched mode power supplies, electric motor drives, battery chargers, etc., The custom power devices like UPQC ...
Chaitanya, Nakka Pruthiv
core  

Practical considerations regarding power factor for nonlinear loads [PDF]

open access: yes, 2004
This material is posted here with permission of the IEEE. Such permission of the IEEE does not in any way imply IEEE endorsement of any of Brunel University's products or services. Internal or personal use of this material is permitted.
Aziz, MMA   +3 more
core   +1 more source

Effect of Line Impedance on the Stability of Shunt Active Power Filter Based on LCL Filter

open access: yesKongzhi Yu Xinxi Jishu, 2018
When shunt active power filter based on LCL filter is used for voltage source type harmonic source, the line and load impedances will not only cause the harmonic amplification but also the stability problem based on current tracking.
REN Lei, YUN Pingping
doaj  

Home - About - Disclaimer - Privacy