Results 111 to 120 of about 572 (173)

Instrumentation for Verification of Shunt Active Power Filter Algorithms. [PDF]

open access: yesSensors (Basel), 2023
Baros J   +6 more
europepmc   +1 more source

Improved control of shunt active power filter using harmony search algorithm [PDF]

open access: yes, 2016
This paper proposes to optimize the control parameters of DC-link voltage shunt active power filter (SAPF) by Harmony Search Algorithm (HSA) and Total Harmonic Distortion (THD) reduction in the system.
Khokhar, S.   +4 more
core  

Grid power quality enhancement by nonlinear control of voltage source inverter

open access: yesJournal of Engineering Research and Reviews
Aim/Background: Maintaining power quality in grid-connected systems with renewable energy sources, particularly solar, is a significant challenge due to stringent requirements for harmonic mitigation. Voltage source inverters serve as critical interfaces
Muhammad imran   +4 more
doaj   +1 more source

Review of Fundamental Active Current Extraction Techniques for SAPF. [PDF]

open access: yesSensors (Basel), 2022
Baros J   +6 more
europepmc   +1 more source

Series active power filter in power conditioning [PDF]

open access: yes, 2009
Power quality has become an important issue nowadays for several reasons, e.g. modern society’s growing dependence on electricity and the fact that poor power quality may generate significant economic losses in few moments.
Turunen, J.
core  

Enhancing power quality: An Adaline algorithm for direct resonance current extraction in shunt active power filter [PDF]

open access: yes
This paper presents an adaptive linear neuron (Adaline) algorithm designed to extract resonance current from the supply current directly. It aims to reduce the computation burden while upholding efficacy in the extraction process.
Baharom, Rahimi   +5 more
core   +2 more sources

Harmonic Mitigation and Energy Savings in 13.2 kV Distribution Feeders via P–Q-Based Shunt Active Filters and Luminaire Retrofit

open access: yesEnergies
This article designs and validates a P-Q-based shunt active power filter (SAPF) to mitigate voltage harmonics in EERSA’s 13.2 kV feeder 1500080T03. A CYMDIST feeder model, calibrated with field measurements, reveals worst-case voltage THD up to 9.48% due
Brandon Condemaita, Milton Ruiz
doaj   +1 more source

Conductance control of a shunt active power filter and active energy buffer [PDF]

open access: yes, 2016
There are many types of control method for shunt active power filter (SAPF) investigated up until now. The authors describe complex methods of determining active filter reference currents or powers.
Szromba, Andrzej
core  

Home - About - Disclaimer - Privacy