Results 91 to 100 of about 8,165,669 (143)

Fuzzy Controlled Shunt Active Power Filter for Line Harmonic Mitigation

open access: yes, 2014
- Epidemic applications of power electronic based non-linear loads result in increase of harmonics in the power system. The current harmonics produced by these non-linear loads result in voltage distortion and leads to various power quality problems.

core  

Harmonic Mitigation and Energy Savings in 13.2 kV Distribution Feeders via P–Q-Based Shunt Active Filters and Luminaire Retrofit

open access: yesEnergies
This article designs and validates a P-Q-based shunt active power filter (SAPF) to mitigate voltage harmonics in EERSA’s 13.2 kV feeder 1500080T03. A CYMDIST feeder model, calibrated with field measurements, reveals worst-case voltage THD up to 9.48% due
Brandon Condemaita, Milton Ruiz
doaj   +1 more source

Capacitor current feedback active damping for Shunt Active Power Filter with output LLCL filter

open access: yes, 2018
10th International Conference on Electrical and Electronics Engineering, ELECO 2017 --29 November 2017 through 2 December 2017 -- --A high-order LLCL has excellent attenuation performance of ripple harmonics generated by VSI.
Buyuk M., Tumay M., Inci M., Tan A.
core   +1 more source

Review of Fundamental Active Current Extraction Techniques for SAPF. [PDF]

open access: yesSensors (Basel), 2022
Baros J   +6 more
europepmc   +1 more source

Fuzzy Logic Control For Three Phase Shunt Active Power Filter (Modeling And Simulation) [PDF]

open access: yes, 2010
The main purpose of this project is to perform studied on fuzzy logic control for a three-phase Shunt Active Power Filter (SAPF) in order to reduce total harmonic distortion and power factor correction in a distribution system supplying non-linear loads.
Aida Yanti Oredi, Aida Yanti
core  

Comparison of active filters topologies in medium voltage distribution power systems [PDF]

open access: yes, 2014
This paper presents the design of different topologies of active power filters to compensate reactive power and harmonics in the medium voltage level of a distribution power system. One pure active filter and two hybrid topologies, are implemented.
Corasaniti, Víctor Fabián   +3 more
core  

Control active power filter for improving power quality in the microgrid [PDF]

open access: yes, 2013
This paper aims at improving the power quality with controlling method shunt active power filter in Micro- grid System. A hybrid compensation system consisting of an active filter and passive filters in the Micro-grid is discussed.
Mohd. Zin, Abdullah Asuhaimi   +3 more
core   +1 more source

Analysis and stabilization for full harmonic compensation oscillation in SAPF system with source current direct control

open access: yesIET Power Electronics
Shunt active power filter (SAPF) has emerged as a promising solution for mitigating harmonic distortions. Due to the interaction between the current inner‐loop of SAPF, source impedance and non‐linear loads, harmonic oscillation issue arises and ...
Yihan Xie   +5 more
doaj   +1 more source