Results 71 to 80 of about 8,165,669 (143)

Design and Analysis of Model Predictive Control based Direct and Indirect Current strategy for Single Phase Shunt Active Power Filter

open access: yesMATEC Web of Conferences, 2018
In this paper presents a comparative analysis of two control method applied to a single phase Shunt Active Power Filter (SAPF). It is about Model Predictive Control (MPC) based Direct Current Control (DCC) and Indirect Current Control (IDCC) strategy ...
Kanagavel Rameshkumar   +2 more
doaj   +1 more source

Optimized DBN‐based control scheme for power quality enhancement in a microgrid cluster connected with renewable energy system

open access: yesIET Renewable Power Generation, Volume 18, Issue 12, Page 1926-1947, 7 September 2024.
The proposed topology implemented in this article is an advanced management approach to enhance power quality, and its effectiveness might be assessed in conjunction with the effects of unpredictability in renewable energy sources. Abstract The increasing energy consumption and changing load variations place a significant burden on the sophisticated ...
Narendiran Sivakumar   +3 more
wiley   +1 more source

Development of Shunt Active Power Filter for Harmonic Reduction using Synchronous Reference Frame with Space Vector Pulse Width Modulation

open access: yesNigerian Journal of Technological Development, 2020
The work aims at development of Shunt Active Power Filter (SAPF) for harmonic reduction. The current harmonics are being caused by nonlinear characteristic of power electronics based equipments which increase power losses and in turn reduce power quality.
Sijuwade Akanni Akintade   +2 more
doaj  

Single-Phase Shunt Active Power Filter Based on a 5-Level Converter Topology

open access: yesEnergies, 2018
This paper presents a single-phase Shunt Active Power Filter (SAPF) with a multilevel converter based on an asymmetric full-bridge topology capable of producing five distinct voltage levels.
José Gabriel Oliveira Pinto   +5 more
doaj   +1 more source

Performance enhancement of shunt active power filter with the application of an adaptive controller

open access: yesIET Generation, Transmission & Distribution, 2020
In this study, an adaptive controller is proposed for shunt active power filter (SAPF) to improve the harmonic compensation performance. The proposed controller forces the source current to become sinusoidal, with less total harmonic distortion and also ...
Pravat Kumar Ray   +1 more
doaj   +1 more source

Improved adaptive notch filter-based active damping method for shunt active power filter with LCL-filter

open access: yes, 2018
The LCL-filter has been recently used with grid-connected converters to mitigate switching ripple harmonics. The LCL-filter presents a better attenuation performance for switching ripple harmonics in comparison with L- and LC-type filters.
Tümay M., Büyük M., Tan A.
core   +2 more sources

REDUKSI NILAI TOTAL HARMONIC DISTORTION PADA INVERTER MULTILEVEL CASCADED H-BRIDGE 5 TINGKAT MENGGUNAKAN RANGKAIAN SHUNT ACTIVE POWER FILTER

open access: yes, 2021
ABSTRAK Panel surya saat ini sudah mulai banyak digunakan karena tidak memiliki emisi gas buang dalam proses konversi energinya. Panel surya biasanya digunakan pada industri dan rumah-rumah.
Wijono, n/a   +2 more
core  

Design and implementation of a modified fourier analysis harmonic current computation technique for power active filters using DSPs [PDF]

open access: yes, 2001
The design and implementation of a harmonic current computation technique based on a modified Fourier analysis, suitable for active power filters incorporating DSPs is presented.
El-Habrouk, M   +3 more
core   +1 more source

Hybrid Renewable Energy System Incorporated With Shunt Active Power Filter With Improved Control Technique for Power Quality Mitigation

open access: yesIEEE Access
This work investigates integrating a shunt active power filter (SAPF) with renewable energy sources (RESs) to enhance harmonic mitigation and overall power system performance. Hybrid renewable energy sources (HRES) combine RESs and manage them with smart
Pradosh Kumar Mishra   +6 more
doaj   +1 more source

Seven Level Inverter Based Shunt Hybrid Active Power Filter Topology for Harmonic Reduction [PDF]

open access: yes, 2020
: This paper presents a three-phase asymmetric cascaded seven level inverter (ACSLI) based Shunt Hybrid Active Power Filter (SHAPF) topology for harmonic reduction in medium voltage test system (MVTS).
B Vamsipriya, G Jayakrishna
core  

Home - About - Disclaimer - Privacy