Results 61 to 70 of about 572 (173)
Fuzzy Controlled Shunt Active Power Filter for Line Harmonic Mitigation [PDF]
- Epidemic applications of power electronic based non-linear loads result in increase of harmonics in the power system. The current harmonics produced by these non-linear loads result in voltage distortion and leads to various power quality problems.
core
An Efficient Multi‐Core DSP Power Management Controller
This work proposes a power management controller for multi‐core DSP architectures, specifically designed for FT‐xDSP. The primary contributions include a clamp request control unit to ensure system stability during asynchronous resets, and a configurable state transition counter that optimizes clock transitions.
Jian Huang +4 more
wiley +1 more source
The integration of renewable power sources with power grids presents many challenges, such as synchronization with the grid, power quality problems and so on.
Bijan Rahmani, Weixing Li, Guihua Liu
doaj +1 more source
The increasing demand for electricity and the impact of the consumption of fossil fuels leads to the need for approaching new alternatives of energy production, namely energy storage systems (ESS) and renewable energy sources (RES).
Catia F. Oliveira +4 more
doaj +1 more source
Nonlinear loads in solar microgrids introduce power quality issues such as harmonics, voltage distortions, and reduced system efficiency. These disturbances negatively impact the stability and performance of microgrid components, leading to increased losses and potential equipment damage.
Exaud Tweve +2 more
wiley +1 more source
This paper employs a second-order sequence filter (SOSF) and proportional–integral (PI) controller to control a hybrid active power filter with photovoltaic (HAPF-PV) through three-level neutral point clamped (NPC) converters.
Ehsan Akbari, Abbas Zare Ghaleh Seyyedi
doaj +1 more source
In this paper, a constrained FCS‐MPC based current controller is introduced for controlling shunt active power filters. In the proposed current controller, the objective function is same as used in the conventional FCS‐MPC and a switching frequency constraint is considered to reduce the average switching frequency. The results obtained from FPGA in the
Shahram Karimi +4 more
wiley +1 more source
In this paper, a refined reference current generation algorithm based on instantaneous power (pq) theory is proposed, for operation of an indirect current controlled (ICC) three-level neutral-point diode clamped (NPC) inverter-based shunt active power ...
Yap Hoon +3 more
doaj +1 more source
Model‐Free Predictive Direct Control of Unified Power Quality Conditioner Based on Ultra‐Local Model
ABSTRACT To enhance the robustness of the unified power quality conditioner (UPQC) with finite control set model predictive control (FCS‐MPC), direct control in the dq coordinate system faces challenges such as complex coordinate transformation, system coupling issue and phase‐locked‐loop delays.
Guifeng Wang +6 more
wiley +1 more source
Comparative Study on the Position of Shunt Active PowerFilters in 25 kV AC Railway Systems [PDF]
AC electrified railway systems show power quality problems such as harmonic current pollution, feeder voltageperturbation, and reactive power demand. These power quality problems have a bad effect on the ACrailway system itself as well as other electric ...
Song, Joongho, Park, Haneol, Hosny, Wada
core