Results 51 to 60 of about 572 (173)

Fuzzy Moving Surface Second‐Order Super Twisting Sliding Mode Control for Direct Power Control of Shunt Active Power Filter

open access: yesIET Power Electronics, Volume 19, Issue 1, January/December 2026.
The present paper proposes Fuzzy Moving Surface Second‐Order Super Twisting Sliding Mode Control (FMS‐SO‐ST‐SMC) for Direct Power Control (DPC) of a Shunt Active Power Filter (SAPF). This method offers flexibility and high robustness against external disturbances with low sensitivity to changes in system parameters that are effectively improved with ...
Behnam Amini   +2 more
wiley   +1 more source

Active Power Filtering Using the ZDPC Method under Unbalanced and Distorted Grid Voltage Conditions

open access: yesEnergies, 2015
In this paper, we propose a new Zero Direct Power Control (ZDPC) technique for active compensation of harmonics and reactive power, using shunt active power filter (SAPF), based on cancellation of instantaneous active and reactive power disturbances by ...
Kamel Djazia   +3 more
doaj   +1 more source

Power Quality Enhancement in Grid‐Connected Photovoltaic Systems Using Hybrid Harbor Seal Whiskers Optimization and Interpretable Generalized Additive Neural Networks

open access: yesInternational Transactions on Electrical Energy Systems, Volume 2026, Issue 1, 2026.
The integration of solar energy into modern power grids supports sustainability and energy efficiency but also introduces power quality (PQ) challenges such as harmonic distortion, voltage sag, swell, and fluctuations. In order to reduce PQ problems in renewable energy systems (RESs), this research proposes a novel hybrid control strategy that combines
M. Hariprabhu   +4 more
wiley   +1 more source

Research Article Fuzzy Logic Controlled Shunt Active Power Filter for Harmonic Compensation and Power Quality Improvement [PDF]

open access: yes, 2014
In this paper, a shunt active power filter based on fuzzy logic controller is modeled, simulated, and tested. The fundament of Instantaneous Reactive Power Algorithm is used for extracting compensated reference harmonic current.
Tahar Bahi, Aziz Boukadoum
core  

Backstepping control of three-phase three-level four-leg shunt active power filter [PDF]

open access: yes, 2017
In this paper, backstepping control for three-level four-leg shunt active power filter (SAPF) system is proposed. The adopted filtering topology requires both a three-dimensional space vector modulation (3DSVM) for controlling the three-level four-leg ...
Barkat, S., Bouzidi, M., Badra, M.S.
core   +2 more sources

Current Control of Three‐Phase Inverter Using a Data‐Driven Model‐Free Adaptive Controller for Power Quality Improvement

open access: yesInternational Transactions on Electrical Energy Systems, Volume 2026, Issue 1, 2026.
This paper introduces a data‐driven model‐free adaptive controller (DDMFAC) as a powerful, practical, and suitable alternative to improve the limitations, challenges, and inherent problems of conventional model–based methods. The proposed method, using input–output data processing independent of the mathematical and systematic model, acts as an ...
Behnam Amini   +3 more
wiley   +1 more source

Robust control of adaptive power quality compensator in Multi-Microgrids for power quality enhancement using puzzle optimization algorithm

open access: yesAin Shams Engineering Journal, 2023
The primary purpose of this paper is to design a novel multi-microgrid connection that uses power compensation methods to improve voltage profiles and reduce harmonic distortions using specific compensation devices in low inertia systems.
Hatem F. Sindi   +4 more
doaj   +1 more source

Seven Level Inverter Based Shunt Hybrid Active Power Filter Topology for Harmonic Reduction [PDF]

open access: yes, 2020
: This paper presents a three-phase asymmetric cascaded seven level inverter (ACSLI) based Shunt Hybrid Active Power Filter (SHAPF) topology for harmonic reduction in medium voltage test system (MVTS).
B Vamsipriya, G Jayakrishna
core  

Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter [PDF]

open access: yes, 2018
In this paper, a shunt active power filter SAPF based on adaptive hysteresis band current controller HBCC is proposed for limiting the harmonics in load current and also compensate the reactive power for 3 phase non linear load.
Zahid Hassan, Gagan Deep Yadav
core   +1 more source

Real‐Time Implementation of Unknown Input Observer‐Based State and Unknown Disturbance Estimation for Series Active Filters

open access: yesInternational Journal of Circuit Theory and Applications, Volume 53, Issue 7, Page 3970-3992, July 2025.
For the series active filter (SAF), a combined controller and observer scheme is proposed. Two controllers—state feedback (SFB) and linear quadratic regulator (LQR)—along with state observers, including the Luenberger observer (LO), proportional–integral observer (PIO), and unknown input observer (UIO), have been designed.
Nagulapati Kiran, I. E. S. Naidu
wiley   +1 more source

Home - About - Disclaimer - Privacy