Results 51 to 60 of about 8,527,080 (142)
This paper employs a second-order sequence filter (SOSF) and proportional–integral (PI) controller to control a hybrid active power filter with photovoltaic (HAPF-PV) through three-level neutral point clamped (NPC) converters.
Ehsan Akbari, Abbas Zare Ghaleh Seyyedi
doaj +1 more source
An Efficient Multi‐Core DSP Power Management Controller
This work proposes a power management controller for multi‐core DSP architectures, specifically designed for FT‐xDSP. The primary contributions include a clamp request control unit to ensure system stability during asynchronous resets, and a configurable state transition counter that optimizes clock transitions.
Jian Huang +4 more
wiley +1 more source
Shunt Active Power Filter System Design for Inter-harmonic [PDF]
Given the complex situations of the grid with inter-harmonics, three-level model of shunt active power filter (SAPF) was built. For the harmonics accurate detection, the CPT principle was used to detect the fundamental component of the grid.
Yi-Jun, Zhang +3 more
core +1 more source
The increasing demand for electricity and the impact of the consumption of fossil fuels leads to the need for approaching new alternatives of energy production, namely energy storage systems (ESS) and renewable energy sources (RES).
Catia F. Oliveira +4 more
doaj +1 more source
Nonlinear loads in solar microgrids introduce power quality issues such as harmonics, voltage distortions, and reduced system efficiency. These disturbances negatively impact the stability and performance of microgrid components, leading to increased losses and potential equipment damage.
Exaud Tweve +2 more
wiley +1 more source
Reactive Power Compensation and Limiting Harmonic Current using Shunt Active Power Filter
In this paper, a shunt active power filter SAPF based on adaptive hysteresis band current controller HBCC is proposed for limiting the harmonics in load current and also compensate the reactive power for 3 phase non linear load.
Zahid Hassan, Gagan Deep Yadav
core +1 more source
Shunt Active Power Filter untuk Meredam Harmonisa Beban Non-Linear Satu Fasa [PDF]
Penggunaan beban non-linear semakin umum digunakan seiring berkembangnya teknologi yang menerapkan komponen elektronika daya di dalamnya. Beban non-linear dapat menimbulkan harmonisa pada jaringan listrik dan mengakibatkan penurunan kualitas daya.
Sudiharto, Indhana +2 more
core +1 more source
In this paper, a refined reference current generation algorithm based on instantaneous power (pq) theory is proposed, for operation of an indirect current controlled (ICC) three-level neutral-point diode clamped (NPC) inverter-based shunt active power ...
Yap Hoon +3 more
doaj +1 more source
In this paper, a constrained FCS‐MPC based current controller is introduced for controlling shunt active power filters. In the proposed current controller, the objective function is same as used in the conventional FCS‐MPC and a switching frequency constraint is considered to reduce the average switching frequency. The results obtained from FPGA in the
Shahram Karimi +4 more
wiley +1 more source
This work presents the application of a hybrid adaptive Kalman filter (HAKF) for the implementation of a shunt active power filter (SAPF), enabling selective harmonic and interharmonic compensation in real time.
Germán Martínez-Navarro +1 more
doaj +1 more source

