Results 131 to 140 of about 979 (161)
Some of the next articles are maybe not open access.
2014 International Conference on Circuits, Power and Computing Technologies [ICCPCT-2014], 2014
Now-a-days use of nonlinear loads in industries has been increased tremendously which are the source of harmonic currents to be injected in supply system. These harmonics creates power quality issue. The most popular solution to eliminate these harmonics is Shunt Active Power Filter (SAPF) because SAPF can eliminate harmonics easily, overcome voltage ...
Nilesh M. Chamat +3 more
openaire +1 more source
Now-a-days use of nonlinear loads in industries has been increased tremendously which are the source of harmonic currents to be injected in supply system. These harmonics creates power quality issue. The most popular solution to eliminate these harmonics is Shunt Active Power Filter (SAPF) because SAPF can eliminate harmonics easily, overcome voltage ...
Nilesh M. Chamat +3 more
openaire +1 more source
Hardware in the loop simulation of Shunt Active Power Filter (SAPF) utilizing RTDS and dSPACE
2017 Brazilian Power Electronics Conference (COBEP), 2017This paper deals with the integration of a Shunt Active Power Filter (SAPF) to the electric power grid and a non-linear load (typically rectifier). The intention is testing the control system by Hardware In the Loop (HIL) simulation under conditions which are closer to the SAPF and the electric power grid reality.
Dalmo C. Silva +4 more
openaire +1 more source
2018 IEEE Applied Power Electronics Conference and Exposition (APEC), 2018
The current-limiting strategy for shunt active power filter (SAPF) will be activated automatically, when the compensation-capacity need exceeds the rated capacity. However, the traditional current-limiting strategy cannot realize the comprehensive protection with optimum objectives.
Wu Cao +4 more
openaire +1 more source
The current-limiting strategy for shunt active power filter (SAPF) will be activated automatically, when the compensation-capacity need exceeds the rated capacity. However, the traditional current-limiting strategy cannot realize the comprehensive protection with optimum objectives.
Wu Cao +4 more
openaire +1 more source
2016 IEEE International Telecommunications Energy Conference (INTELEC), 2016
This paper presents an Inductor-Capacitor-Inductor (LCL) filter with Sinusoidal Pulse Width Modulation (SPWM) based switching control strategy for four-leg Voltage Source Inverter (4LVSI) in Shunt Active Power Filter (SAPF) to compensate load current harmonics and fundamental frequency voltage unbalances at point of common coupling (PCC).
Bharadwaj Kaka, Abhishek Maji
openaire +1 more source
This paper presents an Inductor-Capacitor-Inductor (LCL) filter with Sinusoidal Pulse Width Modulation (SPWM) based switching control strategy for four-leg Voltage Source Inverter (4LVSI) in Shunt Active Power Filter (SAPF) to compensate load current harmonics and fundamental frequency voltage unbalances at point of common coupling (PCC).
Bharadwaj Kaka, Abhishek Maji
openaire +1 more source
Energy, 2016
Abstract In this article, a transformer-less 3P3W SAPF (three-phase three-wire shunt active power filter) integrated into the distributed energy network which embeds line-interactive UPS and bi-directional chopper-fed energy storage equipment. The proposed system operates in two operating modes of line-interactive UPS (uninterruptible power supply ...
Wajahat Ullah Tareen, Saad Mekhilef
openaire +2 more sources
Abstract In this article, a transformer-less 3P3W SAPF (three-phase three-wire shunt active power filter) integrated into the distributed energy network which embeds line-interactive UPS and bi-directional chopper-fed energy storage equipment. The proposed system operates in two operating modes of line-interactive UPS (uninterruptible power supply ...
Wajahat Ullah Tareen, Saad Mekhilef
openaire +2 more sources
2020
The issues related to power quality are becoming stronger; as the sensitive equipment plays a leading role in the power industry, it will pollute the system and increase the cost due to inbuilt compensation and deficiency of implemented regulations. Now, the cost and efficiency of the system are considered nearly at the identical level.
Shivangi Upadhyay, Sachin Singh
openaire +1 more source
The issues related to power quality are becoming stronger; as the sensitive equipment plays a leading role in the power industry, it will pollute the system and increase the cost due to inbuilt compensation and deficiency of implemented regulations. Now, the cost and efficiency of the system are considered nearly at the identical level.
Shivangi Upadhyay, Sachin Singh
openaire +1 more source
An Advanced Shunt Active Power Filter (SAPF) for Non-ideal Grid Using Predictive DPC
IETE Technical Review, 2022Abinash Rath, Gopalakrishna Srungavarapu
openaire +1 more source
International Journal of Electrical Components and Sustainable Energy, 2013
Aliyu Sabo, Noor Izzri Bin Abdul Wahab
openaire +1 more source
Aliyu Sabo, Noor Izzri Bin Abdul Wahab
openaire +1 more source