Results 21 to 30 of about 1,008 (177)

Simulation and Hardware Implementation of Shunt Active Power Filter Based on Synchronous Reference Frame Theory [PDF]

open access: yes, 2018
This paper describes about the Shunt Active Power Filter (SAPF) for the elimination of the current harmonics in the line side. The Active Power Filter is based on the Voltage Source Inverter (VSI) topology.
Annapoorani, Iyswarya   +2 more
core   +4 more sources

PLL-Less Three-Phase Four-Wire SAPF with STF-dq0 Technique for Harmonics Mitigation under Distorted Supply Voltage and Unbalanced Load Conditions

open access: yesEnergies, 2018
This paper presents a non-iterative technique that generates reference current to manage operation of a three-phase four-wire shunt active power filter which employs a three-leg split capacitor voltage source inverter (VSI) topology.
Yap Hoon, Mohd Amran Mohd Radzi
doaj   +1 more source

Synchronous Reference Frame with Finite Impulse Response Filter for Operation of Single-phase Shunt Active Power Filter [PDF]

open access: yesMATEC Web of Conferences, 2021
Power Quality (PQ) has been recognized as one of the main issues in electricity supply worldwide after the invention of nonlinear load. In 2017, PQ problem leads to significant economic losses in the Pan European region.
Tham Zhen Ye   +2 more
doaj   +1 more source

Design and Analysis of Shunt Active Power Filter (SAPF) for Non Linear and Unbalanced Loads

open access: yesInternational Journal of Engineering and Advanced Technology, 2020
Increasing power demand in present situation has to comply with the power generation. Generated power has to meet the quality standards. With the introduction of nonlinear loads like static power converters inject harmonics into the system which effect operation of the system adversely.
Kiran Yaddanapudi   +1 more
openaire   +1 more source

Energy management and harmonic compensation of micro‐grids via multi‐agent systems based on decentralized control architecture

open access: yesIET Renewable Power Generation, Volume 17, Issue 5, Page 1267-1285, 6 April 2023., 2023
Here, a new energy management strategy based on a multi‐agent structure using a hybrid controller is proposed in a grid‐connected AC micro‐grid (MG) with current harmonics compensation. Abstract Here, a new energy management strategy based on a multi‐agent structure is presented by introducing hybrid control of AC micro‐grid (MG), where current ...
Mohammadreza Salehirad   +1 more
wiley   +1 more source

Power outage detection methods for theoperation of a shunt active power flter as energy backup system [PDF]

open access: yes, 2014
This paper presents the study of power outage detection methods that can be applied to a Shunt Active Power Filter (SAPF) with energy backup capability.
A. Moschitta   +5 more
core   +3 more sources

Simulation study on the material stress distribution respect to different angle of ECAP [PDF]

open access: yes, 2022
This research study focused on the influence of channel angle towards stress distribution of material aluminium alloy 5083. The size of the grain is related to the mechanical properties of material.
Kamaruddin, Akmalia Shahira   +1 more
core   +1 more source

A hybrid fuzzy sliding-mode control for a three-phase shunt active power filter [PDF]

open access: yes, 2017
This document is the Accepted Manuscript version of the following article: Mohamed Abdeldjabbar Kouadria, Tayeb Allaoui, and Mouloud Denai, ‘A hybrid fuzzy sliding-mode control for a three-phase shunt active power filter’, Energy Systems, Vol. 8 (2): 297-
B Singh   +16 more
core   +2 more sources

A Novel Single-Phase Shunt Active Power Filter with a Cost Function Based Model Predictive Current Control Technique

open access: yesEnergies, 2022
For a single-phase Shunt Active Power Filter (SAPF) with a two-step prediction, this research presents a modified current control based on a Model Predictive Current Control (MPCC) technique.
Belqasem Aljafari   +3 more
doaj   +1 more source

A fault-tolerant photovoltaic integrated shunt active power filter with a 27-level inverter [PDF]

open access: yes, 2021
This paper introduces a fault-tolerant shunt active power filter (SAPF). The novility in of this work is that it poposes a solutions to increase the reliability of shunt active power filter to maintain its operation under a single-phase open-circuit ...
Madi, Ameen, Saleh, Kamel
core   +3 more sources

Home - About - Disclaimer - Privacy