Comparative assessment of crystallographic and cryo‐EM models in the Protein Data Bank
Raw data obtained by X‐ray crystallography or cryo‐EM result in experimental maps, ultimately fitted by atomic models. Although the physical principles are different, the final results can be viewed, compared, and evaluated in the same way. With cryogenic electron microscopy (cryo‐EM) on track to surpass X‐ray crystallography as the preferred method ...
Alexander Wlodawer +7 more
wiley +1 more source
Impact of using single-file reciprocating system on the quality of root canal treatment treated by undergraduate students. [PDF]
Ameen M +3 more
europepmc +1 more source
In this study, a novel esterase from the thermoacidophilic archaeon Thermoplasma acidophilum was biochemically and structurally characterized. Our results demonstrate that Ta0887 is a highly thermostable esterase that preferentially hydrolyzes p‐nitrophenyl hexanoate and possesses an α‐helical cap domain that likely contributes to its substrate ...
Alejandro Delgado‐Rey +4 more
wiley +1 more source
Assessment of Debris Extrusion in Curved Canals: An In Vitro Analysis of Various Single-File Endodontic Instrumentation Systems. [PDF]
Ahmad MZ.
europepmc +1 more source
Threonine 348 regulates the subcellular localization of PTEN
Thr348 in the C2 domain is a key contributor to PTEN subcellular localization. The PTEN350 fragment and PTENA4 accumulated in the nucleus, whereas PTENK13R,A4 predominantly localized to the plasma membrane. In contrast, substitution of Thr348 with Asp (T348D) disrupted these characteristic localization patterns, resulting in predominant cytoplasmic ...
Takashi Kato, Suzu Tanaka, Miyu Ohashi
wiley +1 more source
Quality of Single-Cone Obturation Using Different Sizes of Matching Gutta-Percha Points of Two Reciprocating Single-File Systems in Curved and Straight Root Canals. [PDF]
Arvaneh S +3 more
europepmc +1 more source
Cell surface CD11c as a neutrophil aging marker molecule
Cell surface CD11chi neutrophils were more aged and had better phagocytic function than CD11c−/lo neutrophils. Transcriptomic analysis of CD11chi neutrophils and CD11c−/lo neutrophils in pediatric population showed that the most difference was seen in infants.
Sophia Koutsogiannaki +5 more
wiley +1 more source
Clinical Evaluation of Root Canal Shaping Ability of a Stainless-steel File System Compared to Two Nickel-titanium Single-file Systems. [PDF]
Mais AO +3 more
europepmc +1 more source
Using fluorescence fluctuation spectroscopy to quantify molecular dynamics within cells
Microscopy techniques like fluorescence correlation spectroscopy (FCS) and number and brightness analysis (N&B) allow to quantify concentrations, diffusion rates, and oligomerization of fluorescently labeled molecules in the living cell. In this protocol the principles of how to set up these types of experiments are described including calibration ...
Mark A. Hink
wiley +1 more source
Comparative evaluation of remaining dentin thickness using single file, two file, and multiple rotary file system - An in vitro CBCT study. [PDF]
Chandar CY +5 more
europepmc +1 more source

