Results 41 to 50 of about 88,367,282 (284)

Real-time fault diagnosis and fault-tolerant control [PDF]

open access: yes, 2015
This "Special Section on Real-Time Fault Diagnosis and Fault-Tolerant Control" of the IEEE Transactions on Industrial Electronics is motivated to provide a forum for academic and industrial communities to report recent theoretic/application results in ...
Cecati, Carlo   +2 more
core   +1 more source

Ground-Fault Recognition in Low-Voltage Ships Based on Variation Analysis of Phase-to-Ground Voltage and Neutral-Point Voltage

open access: yesIEEE Access
Generally, ships use a three-phase power system with low-voltage and ungrounded systems to ensure continuous power supply. In these shipboard power systems, ground faults constitute approximately 95% of all faults.
Ki-Tak Ryu, Yun-Hyung Lee
doaj   +1 more source

Ground Fault Protection Using Open Break Delta Grounding Transformer in Ungrounded System

open access: yesLogic, 2019
One of the most common and difficult problems to solve in distribution power systems is the location and elimination of the ground fault. For the study of an electrical distribution network in ungrounded system operating at 20 kV on the primary and 380 V
Supriyanto Suhono   +2 more
doaj   +1 more source

Fault Tolerant Control of a Seven-phase Drive by Degrees of Freedom Adaptation [PDF]

open access: yes, 2010
La version éditeur est disponible à l'adresse suivante : http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=5472476&isnumber=5472440This paper proposes a simple way to control multi-phase drives in open-phase conditions. Contrary to existing methods,
KESTELYN, Xavier   +5 more
core   +1 more source

The Influence of the Characteristics of the Medium Voltage Network on the Single Line-to-Ground Fault Current in the Resistor Grounded Neutral Networks

open access: yesDesigns, 2021
One important problem in the operation of medium voltage networks is the detection of a single-line-to-ground fault in its incipient state, when the fault resistance values are very high.
Dumitru Toader   +6 more
doaj   +1 more source

Study of a New Approach about Locating Single-phase-to-ground Fault [PDF]

open access: yesAdvances in Intelligent Systems Research, 2013
First this paper briefly analyzes the electric power transient signal of single phase grounding fault, and then the fault characteristics of zero sequence current and bus voltage is obtained by wavelet transformation. Finally by using genetic algorithm to optimize the original weights of back-propagation neural network, as well as taking the fault ...
Jie Yin   +3 more
openaire   +1 more source

An Efficient Control of a Series Connected Two-Synchronous Motor 5-Phase with Non Sinusoidal EMF Supplied by a Single 5-leg VSI: Experimental and Theoretical Investigations [PDF]

open access: yes, 2012
Lien vers la version finale éditeur This paper proposes the control scheme of an original drive which is made up of two 5-phase permanent magnet synchronous machines (PMSM) connected in series.
CHARPENTIER, Jean-Frederic   +3 more
core   +1 more source

Estimation of the minimum level of higher harmonics in the single-phase-to-ground fault current in compensated 6–10 kV networks

open access: yesElektrotehnìka ta Elektroenergetika
Purpose Development of a model for a compensated 6–10 kV network and a methodology for selecting its element parameters based on estimating the minimum level of higher harmonics in the single-phase-to-ground fault current. Methodology. To estimate the
A. E. Shamrai, I.V. Isaiev
doaj   +1 more source

DEVELOPMENT OF A COMPREHENSIVE APPROACH TO DIAGNOSING THE OVERHEAD LINE FAULTS LOCATION IN SINGLE-PHASE GROUND FAULTS BASED ON A DIGITAL SUBSTATION DATA PROCESSING ALGORITHM

open access: yesИзвестия Томского политехнического университета: Инжиниринг георесурсов, 2023
Link for citation: Sushkov V.V., Sukhachev I.S., Sidorov S.V. Development of a comprehensive approach to diagnosing the overhead line faults location in single-phase ground faults based on a digital substation data processing algorithm.
Valery V. Sushkov   +2 more
doaj   +1 more source

Retrospective Analysis of Donor Lymphocyte Infusions in Pediatric Patients With Mixed Chimerism After Hematopoietic Stem Cell Transplantation

open access: yesPediatric Blood &Cancer, EarlyView.
ABSTRACT Background Allogeneic hematopoietic stem cell transplantation (alloHSCT) is an essential therapy for several malignant and nonmalignant diseases, but relapse and graft loss remain the principal threats to its success. Routine monitoring of chimerism and minimal residual disease (MRD) enables early detection of imminent recurrence and guides ...
Carmen Junk   +10 more
wiley   +1 more source

Home - About - Disclaimer - Privacy