Results 1 to 10 of about 49,038 (159)
The paper addresses the issue of identification of the type of single-phase ground fault in medium voltage networks operating mainly with an isolated neutral. By analyzing the published research, the most promising methods for detection of a single-phase
Andrey A. Achitaev +4 more
doaj +4 more sources
Settings of protection are essential to ensure the sensitivity and selectivity needed to detect defects. Making the correct settings requires the calculation of the fault currents with as little error as possible.
Dumitru Toader +4 more
doaj +4 more sources
When the overhead line passes through the forest area, the conductor may contact the line to induce the tree-contact single-phase-to-ground fault (TSF), and the persistence of TSF may induce wildfires, bringing serious consequences.
Jianbo He +6 more
doaj +2 more sources
Reliable fault line selection technology is crucial for preventing fault range expansion and ensuring the reliable operation of distribution networks.
Shi Su +7 more
doaj +2 more sources
Time Estimation Algorithm of Single-Phase-to-Ground Fault Based on Two-Step Dimensionality Reduction
The fault detection time identified by relying on the over-voltage criterion of zero-sequence voltage often lags behind the actual occurrence time of ground faults, which may cause fault protection methods based on transient quantity principles to miss ...
Xin Lin +3 more
doaj +3 more sources
There are some problems existing in the traditional grounding mode of the distribution network. To solve them, this paper proposes a flexible grounding method for neutral point.
Han Zeng +8 more
doaj +3 more sources
Single-phase-to-ground fault in low-current grounding systems represents a serious public safety concern. Low-voltage (LV) sensors, with their growing maturity, can now monitor multiple points of the mid-voltage (MV) distribution network.
Xin Ai, Ai Xin, Mingze ZHANG
exaly +2 more sources
V. Kachesov, A. Lebedev, E. Kitova
exaly +2 more sources
Fault Diagnosis of Power Cable Based on 1DCNN-BiLSTM [PDF]
In order to improve the accuracy of fault diagnosis of power cable failure to ensure a cable fault detection method based on convolution neural network (CNN) and bi-directional long short term memory (BiLSTM) was proposed in this paper.
GAO Chao +3 more
doaj +1 more source
Using Matlab/Simulink Software Package to Investigate Fault Behaviors in HVDC System
Existing studies show that several performance issues will arise in the HVDC link during the three phase-to-ground fault at the side of the inverter and that the DC voltage will oscillate around zero and will not affect the rectifier of the AC system ...
Olumoroti Ikotun +3 more
doaj +1 more source