Results 11 to 20 of about 10,146,497 (282)
Mathematical Modeling of Arc Faults in Networks with Low Single Phase-to-Ground Fault Currents [PDF]
The article comprises the results of the research defining open-flame arcs self-quenching conditions in the event of a single phase-to-ground fault in overhead medium-voltage distribution networks according to existing theories of arc extinguishing.
Brilinskii Andrei +3 more
doaj +2 more sources
The coal mine power supply and distribution system usually adopts the neutral point non-effectively grounded method. Most of the power supply lines in this method use cable lines.
SI Weibin +6 more
doaj +2 more sources
Fault Path Direct-Current Resistance Based Off-Line Single-Phase-To-Ground Fault Location
In order to figure out the off-line transmission line fault location, a new fault location method based on fault path direct current resistance measurement is proposed.
Fuzhi LI +6 more
doaj +2 more sources
Incorporation of fault rock properties into production simulation models [PDF]
This thesis has two aims. First, to investigate the importance of incorporating the multiphase flow properties of faults into production simulation models.
Al-Busafi, Bader
core +7 more sources
The geometry and thickness of deformation-band fault core and its influence on sealing characteristics of deformation-band fault zones [PDF]
Deformation-band faults in high-porosity reservoir sandstones commonly contain a fault core of intensely crushed rock surrounding the main slip surfaces.
Thompson, L.B. +2 more
core +8 more sources
The efficiency of electrical complexes depends directly on the level of power supply system reliability, which comprises extensive and branched distribution networks.
D. Ustinov +4 more
semanticscholar +1 more source
Application of multiple resistive superconducting fault-current limiters for fast fault detection in highly interconnected distribution systems [PDF]
Superconducting fault-current limiters (SFCLs) offer several benefits for electrical distribution systems, especially with increasing distributed generation and the requirements for better network reliability and efficiency.
Burt, Graeme +3 more
core +4 more sources
Fault-tolerant operation of single-phase SR generators [PDF]
This paper studies fault-tolerant operation of multipole single-phase switched reluctance generators (SRGs), in particular, an 8/8-pole switched reluctance machine.
Sawata, T. +9 more
core +3 more sources
Single-phase earth ground faults are the most frequent faults likely to occur but hard to identify in a distribution system, especially in a neutral ineffectively grounded system.
Su Xueneng +7 more
doaj +1 more source
The phase selection and fault location methods of generator stator winding single-phase grounding fault are greatly affected by the transition resistance.
Qinwei Li, Wenchao Jia
doaj +1 more source

