Results 21 to 30 of about 10,043 (293)
FEATURES OF A FAULTY PHASE AT SINGLE PHASE-TO-GROUND FAULTS
Relevance Devices for determining the location of fault on power lines assume a known type of short circuit and faulty phases. However, their algorithms, as a rule, can not distinguish the faulty phase. Therefore, the determination of faulty phases during short circuits on power lines is performed by separate devices – faulty phase selectors.
Vitaly Shabanov, Alexander Sorokin
openaire +1 more source
Research on Arc Grounding Fault Selection Method of Distribution Network Based on Wavelet Analysis [PDF]
Chinese urban low-voltage distribution network capacitance current rose sharply, single-phase ground fault arc was difficult to self-extinguish and easy to produce arc light ground overvoltage and lead to accidents.
LI Jingli +5 more
doaj +1 more source
In order to enhance effectiveness of single-phase ground fault feature extraction and to achieve exactly identification of fault line selection,a new fault line selection method of single phase grounding fault based on wavelet packet and online ...
JI Wen-lu +4 more
doaj +1 more source
Fusion fault line selection method of small current grounding fault based on VMD
At present, the fault line selection method of coal mine distribution network has the problem of fault line selection failure when the relevant fault features are not obvious.
SUN Kongming +5 more
doaj +1 more source
Ground reaction force sensor fault detection and recovery method based on virtual force sensor for walking biped robots [PDF]
This paper presents a novel method for ground force sensor faults detection and faulty signal reconstruction using Virtual force Sensor (VFS) for slow walking bipeds. The design structure of the VFS consists of two steps, the total ground reaction force (
Hashlamon, Iyad +3 more
core +1 more source
High-reliability fault tolerant digital systems in nanometric technologies: Characterization and design methodologies [PDF]
This paper reports the main contribution of a project devoted to the definition of techniques to design and evaluate fault tolerant systems implemented using the SoPC paradigm, suitable for missionand safety-critical application environments.
Gerardin S. +91 more
core +1 more source
Dimensional response analysis of multistorey regular steel MRF subjected to pulselike earthquake ground motions [PDF]
An alternative and efficient procedure to estimate the maximum inelastic roof displacement and the maximum inelastic interstorey drift ratio along the height of regular multi-storey steel MRF subjected to pulse-like ground motions is proposed. The method
Karavasilis, Theodore L. +7 more
core +1 more source
Dimensional response analysis of bilinear systems subjected to non-pulselike earthquake ground motions [PDF]
The maximum inelastic response of bilinear single-degree-of-freedom systems when subjected to ground motions without distinguishable pulses is revisited with dimensional analysis by identifying time scales and length scales in the time histories of ...
Karavasilis, Theodore L. +8 more
core +1 more source
The further identification of fault types for single line-to-ground faults (SLGFs) in distribution networks is conducive to determining the cause of grounding faults and formulating targeted measures for hidden danger treatment and fault prevention.
Yue Liu +4 more
core +1 more source
An improved natural frequency based method is proposed to accurately locate faults in transmission lines. The method only requires three phase instantaneous current measurements at the local terminal of the line and is compatible with protective relays ...
Yuan Nie, Yu Liu, Dayou Lu, Binglin Wang
doaj +1 more source