Estimating locations of single-phase-to-ground faults of ungrounded distribution systems

IEEE PES ISGT Europe 2013, 2013
This paper proposes a new method for determining single-phase-to-ground fault locations of ungrounded distribution systems based on the measurements collected from the feeder breakers and intelligent switches during the fault. The method first narrows down the possible faulted area into a specific feeder section based on the reactive power factors of ...
Hongbo Sun 0003   +4 more
openaire   +1 more source

Single-phase grounding fault identification and fault line selection for compensation grid

Proceedings of The 7th International Power Electronics and Motion Control Conference, 2012
A new grounding fault line selection method based on small-world network theory is proposed in order to solve the problems existing in grounding fault line selection device of compensation grid, such as that the correct rate of grounding fault line selection is not high and the selection device cannot recognize high-impedance and low-impedance ...
null Chen Zhongren   +2 more
openaire   +1 more source

Ground-fault loop impedance calculations in single-phase systems

49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference, 2013
Protection against electric shock in low-voltage installations by automatic disconnection of the supply must be provided in compliance with applicable national or international standards. Such regulations (e.g. National Electrical Code in the U.S., IEC 60364, BS 7671 in the U.K., etc.) take into account the earthing system of the installation, such as ...
Haijun Liu, Massimo Mitolo, Jun Qiu
openaire   +1 more source

Study on Fault Location of Single-Phase-to-Ground for Distribution Network

Advanced Materials Research, 2012
The AC-DC method (the AC method combined with the DC method) has integrated the superiority of the AC method’s easy measurement and the DC method’s reliability, so it has achieved some degree of use. The method before only took the ground resistor as the condition of combination, so it is not perfect.
Li Zhang, Xiu Yuan Yang, Jun Ling Ren
openaire   +1 more source

Detection of places of single-phase ground fault by frequency of the resonance

2016 57th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON), 2016
Long-term single-phase ground fault in overhead 6–35 kV power lines with isolated neutral, accompanied by intermittent arc, lead to overvoltage and damage of electrical equipment. In turn, precise localisation of the damaged sections of the overhead power lines is a challenging task, as external inspection of power lines takes a lot of time, effort and
Aleksander Fedotov   +3 more
openaire   +1 more source

Fault line Selection of Single Phase Grounding Fault in Small-Current Ground System Based on Reactive Current

2019 IEEE Innovative Smart Grid Technologies - Asia (ISGT Asia), 2019
It is difficult to select fault line accurate when single phase grounding faults occur in small-current ground system. The manuscript proposed a novel fault line selection scheme base on reactive current. According to theoretical analysis, the variation of current after the occurrence of single phase short circuit is mainly composed of capacitive ...
Li Shilong   +4 more
openaire   +1 more source

A New Fault Location Algorithm for Single Phase to Ground Faults in Power Distribution Network

2010 International Conference on Measuring Technology and Mechatronics Automation, 2010
A new fault location algorithm for distribution network is proposed based on the wide-area synchronizing information. The algorithm is based on the distributed parameters model in the small current neutral grounding system, and constructed a fault location function according to the relationships between the fault current and fault distance, which fully
Shu Tian, Xiaowei Wang, Juanjuan Wang
openaire   +1 more source

Recognition of the Single-Phase Ground Fault in Power Distribution System

Key Engineering Materials, 2011
For power distribution systems, recognizing the single-phase ground fault is very difficult because there are several faults with similar features. This paper presents a novel method that can help to overcome this difficulty. The idea is to turns the original fault info into a whole system with transient state, steady state and transition state ...
openaire   +1 more source

Modeling and simulation analysis of single phase arc grounding fault based on MATLAB

Proceedings of 2011 International Conference on Electronic & Mechanical Engineering and Information Technology, 2011
The single phase arc grounding fault is a main fault form in medium voltage distribution networks. It is essential to build an accurate grounding arc model for fault analysis. In this paper, a new grounding arc model is built based on the MATLAB with the arc gap energy-balance theory.
Ran Yu 0003   +6 more
openaire   +1 more source

A survey on faulty line selection technology for single-phase-to-ground fault in China

2013 IEEE Industry Applications Society Annual Meeting, 2013
Single-phase-to-ground fault is difficult to detect with traditional methods in NIEPS because of minor fault current, fault arc, harmonics influence and the protection principle limitation. In order to improve the precision and reliability of traditional faulty line selection technologies for NIEPS, more attention has been paid by many researchers over