Results 281 to 290 of about 288,989 (348)
Some of the next articles are maybe not open access.

Single-phase grounding fault identification and fault line selection for compensation grid

Proceedings of The 7th International Power Electronics and Motion Control Conference, 2012
A new grounding fault line selection method based on small-world network theory is proposed in order to solve the problems existing in grounding fault line selection device of compensation grid, such as that the correct rate of grounding fault line selection is not high and the selection device cannot recognize high-impedance and low-impedance ...
null Chen Zhongren   +2 more
openaire   +1 more source

A fault location method for single-phase grounding fault in distribution network

The 27th Chinese Control and Decision Conference (2015 CCDC), 2015
The single-phase grounding fault is the most common fault among all types of faults in distribution network. It is of great importance to locate the single phase grounding fault accurately and quickly for reducing economic losses. Aiming at the location of single-phase grounding fault in distribution network, this paper puts forward a new fault ...
Kang Zhongjian, Liu Ruiying, Cao Yang
openaire   +1 more source

Transient processes at single phase-to-ground faults in combined grounded networks

2012 Electric Power Quality and Supply Reliability, 2012
This paper deals with the combined method of neutral grounding when a high-value resistor is continuously connected to a neutral in parallel with a Petersen coil. Monitoring of processes at single phase-to-ground faults was organized in the 6 kV network of the large-scale iron and steel plant.
Andrey Shirkovets   +3 more
openaire   +1 more source

Zero-Sequence Current and Voltage Control Strategy of Multiple MMCs for Single-Phase Ground Fault Protection in AC–DC Hybrid Distribution Networks

IEEE transactions on power electronics
The ac/dc hybrid distribution network (HDN) is facing great challenges under single-phase ground (SPG) fault. To ensure the continuous and stable operation of ac/dc HDNs, it is essential that the converters have fault control and relay protection ...
Youwen Zhang   +6 more
semanticscholar   +1 more source

Synthetic Zero-Sequence Signal-Based Intelligent Location Method for Single-Phase Ground Fault in Distribution Networks

IEEE Transactions on Instrumentation and Measurement
Distribution system structures are intricate and variable, with single-phase ground (SPG) fault occurring frequently. Existing section location methods for SPG faults are often influenced by manually set thresholds, resulting in low accuracy.
Mou-fa Guo   +3 more
semanticscholar   +1 more source

A Single-Phase to Ground Fault Identification Method Based on Extremely Low Frequency Current Detection in Distribution Grids

IEEE Transactions on Power Delivery, 2022
The single-phase to ground fault (SPGF) is very common in power grids. To decrease the fault’s influence on the power supply’s reliability, the neutral point is usually grounded via the Petersen coil, significantly reducing the outage rate. Nevertheless,
Shiwu Yang   +5 more
semanticscholar   +1 more source

Increase Effectiveness Functioning of Protection against Single-Phase Ground Fault Electrical Networks Medium Voltage

IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering, 2020
The article presents the results obtained by studies of the functioning stability of protection against mining enterprise distribution networks single-phase ground faults of 6-10 kV.
D. Pelenev, B. Abramovich, K. Babyr
semanticscholar   +1 more source

Single-Phase Ground Fault Location of Distribution Network with DG Based on CEEMD

2020 Asia Energy and Electrical Engineering Symposium (AEEES), 2020
When a single-phase ground fault occurs in the resonant grounding system, the arc suppression coil only compensates for the power frequency zero sequence current, but has little effect on the non-power frequency zero sequence current.
Qin Qingshan   +3 more
semanticscholar   +1 more source

Valve-Side Single-Phase-to-Ground Fault Analysis in Bipolar MMC-HVDC Systems With Hybrid SMs

IEEE Transactions on Power Delivery
This letter presents a comprehensive fault analysis for a modular multilevel converter high-voltage direct current (MMC-HVDC) system with hybrid half-bridge submodules (HBSMs) and full-bridge SMs (FBSMs) under valve-side single-phase-to-ground (SPG ...
P. Sun   +4 more
semanticscholar   +1 more source

Transient Component-Based Distribution Network Single-Phase Ground Fault Location

Applied Mechanics and Materials, 2013
The paper study the single-phase ground Fault Location. Which analysis neutral non-effectively grounded distribution network transient characteristics of single-phase. and verify the HHT method accuracy that through the actual system simulation of single-phase ground fault experiments .It proposed the fault localization criterion which is based on ...
Zeng Ping Wang, Jia Liu, Wei Hua Luo
openaire   +1 more source