Short circuit study of fixed speed wind turbines with STATCOM in distribution networks [PDF]
The increased penetration of wind farm in distribution networks has brought changes in the performance of the whole system. Such disadvantages when connecting one of these distributed generation sources is reduced voltage and power stability of the AC ...
Darwish, M, Naain, MM, Zobaa, AF
core +1 more source
Sequence determinants of RNA G‐quadruplex unfolding by Arg‐rich regions
We show that Arg‐rich peptides selectively unfold RNA G‐quadruplexes, but not RNA stem‐loops or DNA/RNA duplexes. This length‐dependent activity is inhibited by acidic residues and is conserved among SR and SR‐related proteins (SRSF1, SRSF3, SRSF9, U1‐70K, and U2AF1).
Naiduwadura Ivon Upekala De Silva +10 more
wiley +1 more source
Aiming at the problems that the existing arc suppression cabinet technology cannot adjust the zero sequence voltage flexibly and the control and hardware implementation of active arc suppression equipment based on power electronics are difficult, a new ...
Wu Lifang +7 more
doaj +1 more source
Menentukan Lokasi Gangguan dengan Metode Simple Reactance dan Takagi pada Saluran Distribusi Bangko PT. Chevron Pacific Indonesia Menggunakan Software ETAP 12.6.0 [PDF]
Accurate estimastion of fault location is essential for reliability of power system. For this purpose, fault location algorithms are studied and compared in this paper.
Agus, Y. S. (Yellyna) +1 more
core
The Ile181Asn variant of human UDP‐xylose synthase (hUXS1), associated with a short‐stature genetic syndrome, has previously been reported as inactive. Our findings demonstrate that Ile181Asn‐hUXS1 retains catalytic activity similar to the wild‐type but exhibits reduced stability, a looser oligomeric state, and an increased tendency to precipitate ...
Tuo Li +2 more
wiley +1 more source
In ultra-high voltage (UHV) AC transmission systems, single-phase to ground faults account for more than 80 % of all faults. If reclosing is performed blindly under permanent fault conditions after a single-phase to ground fault, the system may suffer ...
Yikai Wang +8 more
doaj +1 more source
Analisa Gangguan Satu Fasa Ke Tanah Yang Mengakibatkan Sympathetic Trip Pada Penyulang Yang Tidak Terganggu Di PLN APJ Surabaya Selatan [PDF]
Twenty kilovolts power distribution network system at East Java use high resistance (500 ?) grounding system that makes maximum single phase to ground fault current 25 Amperes. To detect this fault current, a Directional Ground Relay (DGR) is used.
Kongdoro, R. (Rusli) +2 more
core
Improved transient simulation of salient-pole synchronous generators with internal and ground faults in the stator winding [PDF]
An improved model for simulating the transient behavior of salient-pole synchronous generators with internal and ground faults in the stator winding is established using the multi-loop circuit method.
Bi, D.Q. +4 more
core +1 more source