A fault location method for single-phase grounding fault in distribution network

The 27th Chinese Control and Decision Conference (2015 CCDC), 2015
The single-phase grounding fault is the most common fault among all types of faults in distribution network. It is of great importance to locate the single phase grounding fault accurately and quickly for reducing economic losses. Aiming at the location of single-phase grounding fault in distribution network, this paper puts forward a new fault ...
Kang Zhongjian, Liu Ruiying, Cao Yang
openaire   +1 more source

Transient processes at single phase-to-ground faults in combined grounded networks

2012 Electric Power Quality and Supply Reliability, 2012
This paper deals with the combined method of neutral grounding when a high-value resistor is continuously connected to a neutral in parallel with a Petersen coil. Monitoring of processes at single phase-to-ground faults was organized in the 6 kV network of the large-scale iron and steel plant.
Andrey Shirkovets   +3 more
openaire   +1 more source

Identification of Fault Line Selection and Section for Single-Phase Ground Fault in Small Current Grounding System

2020 5th International Conference on Power and Renewable Energy (ICPRE), 2020
The fault characteristics of the small current grounding system are not obvious when the fault occurs. Currently, it is hard to accurately select and locate the ground fault in the small current grounding system. Therefore, in this paper, a scheme of fault grounding line selection and location is proposed based on the characteristic of the zero ...
Kaiji Liao   +4 more
openaire   +1 more source

A new single-phase-to-ground fault-detecting relay

Electrical Engineering, 1942
In the application of differential relays the need for a supervising relay which will detect the existence of a single-phase-to-ground fault condition to the exclusion of all others has frequently arisen. Heretofore, the only scheme available has been to utilize a relay energized by zero-sequence quantities. Generally, the relay has been energized by a
openaire   +2 more sources

Estimating locations of single-phase-to-ground faults of ungrounded distribution systems

IEEE PES ISGT Europe 2013, 2013
This paper proposes a new method for determining single-phase-to-ground fault locations of ungrounded distribution systems based on the measurements collected from the feeder breakers and intelligent switches during the fault. The method first narrows down the possible faulted area into a specific feeder section based on the reactive power factors of ...
Hongbo Sun 0003   +4 more
openaire   +1 more source

Single-phase grounding fault identification and fault line selection for compensation grid

Proceedings of The 7th International Power Electronics and Motion Control Conference, 2012
A new grounding fault line selection method based on small-world network theory is proposed in order to solve the problems existing in grounding fault line selection device of compensation grid, such as that the correct rate of grounding fault line selection is not high and the selection device cannot recognize high-impedance and low-impedance ...
null Chen Zhongren   +2 more
openaire   +1 more source

Ground-fault loop impedance calculations in single-phase systems

49th IEEE/IAS Industrial & Commercial Power Systems Technical Conference, 2013
Protection against electric shock in low-voltage installations by automatic disconnection of the supply must be provided in compliance with applicable national or international standards. Such regulations (e.g. National Electrical Code in the U.S., IEC 60364, BS 7671 in the U.K., etc.) take into account the earthing system of the installation, such as ...
Haijun Liu, Massimo Mitolo, Jun Qiu
openaire   +1 more source

Study on Fault Location of Single-Phase-to-Ground for Distribution Network

Advanced Materials Research, 2012
The AC-DC method (the AC method combined with the DC method) has integrated the superiority of the AC method’s easy measurement and the DC method’s reliability, so it has achieved some degree of use. The method before only took the ground resistor as the condition of combination, so it is not perfect.
Li Zhang, Xiu Yuan Yang, Jun Ling Ren
openaire   +1 more source

Detection of places of single-phase ground fault by frequency of the resonance

2016 57th International Scientific Conference on Power and Electrical Engineering of Riga Technical University (RTUCON), 2016
Long-term single-phase ground fault in overhead 6–35 kV power lines with isolated neutral, accompanied by intermittent arc, lead to overvoltage and damage of electrical equipment. In turn, precise localisation of the damaged sections of the overhead power lines is a challenging task, as external inspection of power lines takes a lot of time, effort and
Aleksander Fedotov   +3 more
openaire   +1 more source

Fault line Selection of Single Phase Grounding Fault in Small-Current Ground System Based on Reactive Current

2019 IEEE Innovative Smart Grid Technologies - Asia (ISGT Asia), 2019
It is difficult to select fault line accurate when single phase grounding faults occur in small-current ground system. The manuscript proposed a novel fault line selection scheme base on reactive current. According to theoretical analysis, the variation of current after the occurrence of single phase short circuit is mainly composed of capacitive ...
Li Shilong   +4 more
openaire   +1 more source