SLG(Single-Line-to-Ground) Fault Location in NUGS(Neutral Un-effectively Grounded System) [PDF]
This paper reviews the SLG(Single-Line-to-Ground) fault location methods in NUGS(Neutral Un-effectively Grounded System), including ungrounded system, resonant grounded system and high-resistance grounded system which are widely used in Northern Europe ...
Zhang Wenhai +6 more
doaj +4 more sources
In the neutral ungrounded distribution network, the removal of permanent single-line-to-ground (SLG) fault easily leads to saturation of the electromagnetic voltage transformers (PT), which may cause ferroresonance overvoltage and PT failure.
Pan Lu +6 more
doaj +3 more sources
Earlier studies have reported some calculation methods for commutation failure fault level (CFFL) in line-commutated-converter based high-voltage direct current (LCC-HVDC) system under single-line-to-ground (SLG) faults.
Renlong Zhu +6 more
doaj +3 more sources
This paper proposes a fault location method employing wavelet fuzzy neural network to use post-fault transient and steady-state measurements. When single line to ground fault (SLG) occurs in the distribution lines of an industrial system, the transient feature is distinct and the high frequency components in the transients can be employed to reveal ...
Fan Chunju +4 more
openaire +3 more sources
In high‐impedance grounded distribution networks which are common in many countries, single line‐to‐ground (SLG) fault diagnosis is difficult due to weak fault characteristics, noise interference, three‐phase unbalanced operation's influence and so on.
Yajie Li, Xiaoli Meng, Xiaohui Song
openaire +3 more sources
To suppress the arc current in the single line-to-ground (SLG) fault in neutral isolated distribution network, a two-phase current injection method is proposed for the revised static synchronous compensator (STATCOM), as an extra function during the SLG ...
Yangming Chen +3 more
doaj +3 more sources
In order to achieve selective ground fault protection for bus-connected Powerformers and improve the reliability of the protection scheme, this paper presents a novel stator single-line-to-ground (SLG) fault protection scheme for bus-connected ...
Yuanyuan Wang +5 more
doaj +3 more sources
A Novel Protection Method for Single Line-to-Ground Faults in Ungrounded Low-Inertia Microgrids
This paper proposes a novel protection method for single line-to-ground (SLG) faults in ungrounded low-inertia microgrids. The proposed method includes microgrid interface protection and unit protection. The microgrid interface protection is based on the
Liuming Jing +3 more
doaj +3 more sources
In the non‐effectively grounding distribution system, residual current under single‐line‐to‐ground (SLG) fault threatens the safety of human being and power supply equipment. Active arc suppression device has been proved to be effective for SLG fault arc
Bishuang Fan +6 more
doaj +1 more source
Many sensors like digital fault indicators (DFIs) have been applied and promoted in distribution systems. The sensors can provide a technical mean for single‐line‐to‐ground (SLG) fault section location, but there are still some feature extraction and ...
Jian‐Hong Gao +3 more
doaj +1 more source